CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
26
MN
99/01/08 13:28
FP 1
DLC card down
DLC Failure Kind : Terminal failure (Station number = 2000)
Data = (05 00 80 20 00 FF FF FF)
26
MN
99/01/08 13:28
FP 1
DLC card down
DLC Failure Kind : Terminal not connected (Station number = 2000)
Data = (06 00 80 20 00 FF FF FF)
26
MN
99/01/08 13:28
FP 1
DLC card down
DLC Failure Kind : Terminal circuit failure (Station number = 2000)
Data = (08 00 80 20 00 FF FF FF)
27
MN
99/01/08 13:27
FP 0
Synchronism of DPC missed
DPC on the side of a partner (DPC Number = 0001FFFF)
Data = (00 00 01 FF FF FF FF FF)
27
MN
99/01/08 13:27
FP 0
Synchronism of DPC missed
DPC on the side of oneself (DPC Number = 0005FFFF)
Data = (01 00 05 FF FF FF FF FF)
28
MN
99/01/08 13:28
AP
10
SMDR output buffer memory overflow
(Memory Kind = 00 Overflow kind : External relay turns ON and OFF)
Data = (00 00 FF FF FF FF FF FF)
2B
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT connection down (CS/ZT No. = 10)
Data = (00 04 00 10 31 01 FF FF)
2B
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT carrier has no space (CS/ZT No. = 10)
Data = (01 04 00 10 FF FF FF FF)
Table 1-9 Example of Fault Restoration Display Using MATWorX
Fault
Alarm
Date
CPU
Description
18
-
99/01/08 13:26
MP
FP/AP card returned to normal condition
(FP/AP NO. = 52)
Data = (F4 FF FF FF FF FF FF FF)
19
-
99/01/08 13:26
MP
Power failure returned to normal condition
Recover Kind : AC input failure
Data = (00 01 02 FF FF FF FF FF)
19
-
99/01/08 13:26
MP
Power failure returned to normal condition
Recover Kind : fuse break
Data = (01 02 00 FF FF FF FF FF)
19
-
99/01/08 13:26
MP
Power failure returned to normal condition
Recover Kind : PWR alarm
Data = (02 00 01 FF FF FF FF FF)
30
-
99/01/08 13:28
AP 5
DTI line returned to normal condition
PCM loss
Data = (F0 FF FF FF FF FF FF FF)
30
-
99/01/08 13:28
AP 5
DTI line returned to normal condition
Frame loss
Data = (F1 FF FF FF FF FF FF FF)
Table 1-8 Examples of Fault Occurrence Display Using
MATWorX or MATWorX Studio (Continued)
Fault
Alarm
Date
CPU
Description
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Page 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Page 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...