CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 93
PN-AP00-A
(DBM)
RUN lamp is not
flashing
Abnormal operation
of DBM card
Confirm the programming data: CM05.
Check to see if the SENSE switch is set
as per the AP Number (04-15)
assigned by CM05.
Reset the MB switch.
(Down
→
Up
→
Down)
Check the setting of SW1.
SW1-1: ON
SW1-2: ON
SW1-3: ON
SW1-4: OFF
If the fault cannot be cleared, replace
the card.
PN-AP00-B
(AP00)
RUN lamp is not
flashing
Abnormal operation
of AP00 card
Confirm the programming data: CM05.
Check to see if the SENSE switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05.
Reset the MB switch.
(Down
→
Up
→
Down)
Check the setting of SW1.
SW1-1: ON
SW1-2: ON
SW1-3: ON
If the fault cannot be cleared, replace
the card.
PN-AP01
(AP01)
RUN lamp is not
flashing
Abnormal operation
of AP01 card
Confirm the programming data: CM05.
Check to see if the SENSE switch is set
as per the AP Number (04-15)
assigned by CM05.
Reset the MB switch.
(Down
→
Up
→
Down)
If the fault cannot be cleared, replace
the card.
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT
CONTENT
REMEDIAL ACTION
1
2
3
4
5
1
2
3
4
5
1
2
3
4