NEAX2000
IVS
2
Maintenance Manual
Page 84
ND-70926
(E),
Issue
3.0
CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
26
DLC card down
DLC Failure Kind 05: Terminal
failure
Replace the terminal with a known
good one and check to see if the
same failure occurs.
DLC Failure Kind 08: Terminal
circuit failure
Replace the terminal with a known
good one and check to see if the
same failure occurs.
27
Synchronism of DPC
missed
3:
XX XX XX XX
DPC Failure Kind
DPC Number
DPC Failure Kind 00: DPC on the
side of
partner
Check the switch setting of
DPC on the side of partner.
If the fault cannot be cleared,
replace the card.
DPC Failure Kind 01: DPC on the
side of
oneself
Check the switch setting of
DPC.
If the fault cannot be cleared,
replace the card.
28
SMDR output buffer
memory overflow
3:
XX XX XX XX
Memory Kind
)
Memory kind 00: Billing memory
block
Memory kind 01: Host CPU No. 0
output buffer
memory block
28
SMDR output buffer
memory overflow
Memory kind 02: Host CPU No. 1
output buffer
memory block
Memory kind 03: Automatic print
buffer memory block
Confirm if the Printer power is on
or there are paper.
Memory kind 04: Notice of the rest of
memory block
numbers in the
system
Memory kind 05: CCIS output buffer
memory block
Memory kind 06: CS report traffic
data memory block
Table 2-3 Remedial Action on Each Fault Kind (Continued)
FAULT
KIND
NUMBER
FAULT CONTENT
FAULT INFORMATION
REMEDIAL ACTION
1
2
1
2
1
2
1
2
1
2
1
2
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Page 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Page 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...