CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 17
: Kind of System Initialization information (Upper digit)
1:
Program address information
2:
Receive command information
F: No system initialization information
: Initial Kind (Lower digit)
0:
Power On Initialize
1:
Initialize by Reset Button (SW1)
2:
Serious Failure 1
3:
Serious Failure 2
4:
Not used
5:
Serious Failure 3
6:
Serious Failure 4
7:
Serious Failure 5
8:
Serious Failure 6
9:
SW3 was changed to 0
A: Serious Failure 7
B: Initialize by CAT/MAT
C: Not used
D: Not used
E: Not used
F: Not used
35
36
DLC Failure
Kind
LEN
Station No.
37
DPC
Failure
Kind
DPC No.
38
Memory
Kind
3B
Fault Kind
AP No.
CS/ZT Interface No.
Table 1-7 Fault Restoration Information (Continued)
FAULT
KIND
NUMBER
5
6
7
8
9
10
11
12
o
p
q
r
s
t
y
z
A
a
b