Page 126
ND-70926
(E),
Issue
3.0
CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
(3) If Dial Tone is returned after seizing
the original trunk, there is a
problem with the distant office, the
Carrier Equipment or the line.
(4) If not, check for trouble with wiring
on the MDF and the trunk card.
Any dialed digit is not
transmitted to the distant office.
(1) System Data Programming for the
trunk route: CM35 YY=01, 08, 20
(2) When the Sender Start condition is
set to Wink or Delay Dial by CM35
YY=20, check if answer signal is
returned from the distant office.
(1) Trunk card
(2) FP card
(3) MP card
B
C
~
MDF
DT
ODT
ODT
E
M
E
M
CHECK
REPLACE