2-2. Replacing this product
The following describes procedures to hot-swap a RAID controller in a dual RAID controller configuration.
a)
To replace a failed RAID controller:
1) Confirm that either of controller fault LEDs on rear of RAID controller is lit.
2) Shutdown the server connected to the failed RAID controller, and remove the SAS cable
connected to the failed RAID controller.
3) Remove the failed RAID controller when the disk array unit is turned on.
4) Wait for 60 seconds or more, and then install a new RAID controller.
5) Confirm that the both controller LEDs on the rear of RAID controller are lit
If they are not lit, remove and install the RAID controller again.
6) Confirm with the disk array unit’s management software that the operating system can recognize
the new RAID controller.
48
Summary of Contents for N8190-148
Page 36: ... 7 Advanced Settings のアイコンをクリックします クリック 34 ...
Page 37: ... 8 Single Controller Mode が無効 チェックマーク無し となっていることを確認してください 確認 以上で増設作業は完了となります 35 ...
Page 40: ... 6 交換を行ったコントローラが正常に認識できていることを確認します 確認 38 ...
Page 48: ...7 When the RAID configuration is created click the Advanced Setting icon Click 46 ...
Page 52: ...7 Confirm the NEW RAID controller ready Confirm 50 ...