CHAPTER 3 HOW TO USE MINICUBE2 WITH V850 MICROCONTROLLER
User’s Manual U18371EJ1V0UM
43
3.3.4 Usage examples
This section describes a series of basic operations using the QB-Programmer, using the
µ
PD70F3732 as an
example. The operations from execution of the [Autoprocedure (EPV)] command to programming for the target
device are described. For other commands and their applications, refer to the
QB-Programmer Programming
GUI Operation User
'
s Manual
.
The conditions used for a series of operations in this section are as follows.
<Target system>
Target device:
µ
PD70F3732
Power supply voltage:
5 V (supplied from MINICUBE2)
Communication channel:
CSI-H/S, 2 MHz
<MINICUBE2>
Switches:
Mode select switch: M2
Power select switch: 5
<QB-Programmer>
Parameter file:
70F3732.PRM
Clock setting:
5 MHz, x4 (oscillator on the target system side)
Operation mode:
chip
Program file:
sample.hex
Command options:
[Blank check before Erase] selected
[Read verify after Program] selected
[Security flag after Program] selected
Security function:
[Disable Read] selected