(2) Manually switching the reset signal with jumper
Figure 6-5 illustrates the circuit connection for the case where the reset signal is switched using the jumper,
with or without MINICUBE2 connected. This connection is simple, but the jumper must be set manually.
Figure 6-5. Circuit Connection for Switching Reset Signal with Jumper
RESET_OUT
RESET_IN
Target device
_RESET
Reset connector
RESET signal
Target connector
Jumper
1
2
3
RESET_OUT
RESET_IN
Target device
_RESET
Reset connector
RESET signal
Target connector
Jumper
1
2
3
* Jumper setting
When MINICUBE2 is connected:
1-2 shorted
When MINICUBE2 is not connected: 2-3 shorted
(3) Resetting the target device by power-on clear (POC) only
Figure 6-6 illustrates the circuit connection for the case where the target device is only reset via POC without
using the reset pin. RESET_OUT is valid only when the debugger is running or during flash programming.
Figure 6-6. Circuit Connection for the Case Where Target Device Is Only Reset via POC
RESET_OUT
RESET_IN
Target device
_RESET
Target connector
V
DD
1 to 10 k
Ω
RESET_OUT
RESET_IN
Target device
_RESET
Target connector
V
DD
1 to 10 k
Ω