CHAPTER 3 HOW TO USE MINICUBE2 WITH V850 MICROCONTROLLER
User’s Manual U18371EJ1V0UM
48
(3) Execution of [Autoprocedure (EPV)] command
Click the [Device] menu on the menu bar and then click [Autoprocedure (EPV)].
The [Blank Check], [Erase] (if the flash memory in the target device is not blank), [Program], [Verify], and
[Security] commands are executed for the target device sequentially. The mode LED on MINICUBE2 flashes
yellow during execution. When the command execution is completed normally, the mode LED glows green
and the following window appears.
Figure 3-25. Completion of [Autoprocedure (EPV)] Command Execution