CHAPTER 4 HOW TO USE MINICUBE2 WITH 78K0 MICROCONTROLLER
User’s Manual U18371EJ1V0UM
67
(3) Manually switching the reset signal with jumper
Figure 4-16 illustrates the circuit connection for the case where the reset signal is switched using the jumper,
with or without MINICUBE2 connected. This connection is simple, but the jumper must be set manually.
Figure 4-16. Circuit Connection for Switching Reset Signal with Jumper
RESET_OUT
RESET_IN
Target device
_RESET
Reset connector
RESET signal
Target connector
Jumper
1
2
3
RESET_OUT
RESET_IN
Target device
_RESET
Reset connector
RESET signal
Target connector
Jumper
1
2
3
* Jumper setting
When MINICUBE2 is connected:
1-2 shorted
When MINICUBE2 is not connected: 2-3 shorted
When a 10-pin connector is used, pins 1 and 2 of the target connector can also be used as the jumper, as
shown in Figure 4-17.
Figure 4-17. Jumper Connection When 10-Pin Connector Is Used
RESET_IN
RESET_OUT
1
2
3
4
5
6
7
8
9
10
Target device
_RESET
Reset connector
RESET signal
Target connector
RESET_IN
RESET_OUT
1
2
3
4
5
6
7
8
9
10
Target device
_RESET
Reset connector
RESET signal
Target connector