Configuring Your System 3-31
To disable the FRB Timer Enable:
1.
Power off the system and remove the left panel as described in
Chapter 4 of this guide.
2.
Move the FRB Timer Enable jumper from pins 1-2 to pins 2-3. Refer
to “Configuring System Board Jumpers” to see the location of this
jumper.
3.
Replace the panel and power on the system.
4.
Power on the system and wait for POST to complete.
5.
Run the SSU to configure the system.
Chassis Intrusion Detection Jumper
The chassis contains an alarm switch that sends a notification signal to
the server management software if a cover is removed. The jumper at
pins 5, 6, and 7 controls whether this alarm feature is enabled or
disabled.
!
CAUTION
For normal operation leave Chassis Intrusion Detection
jumper at factory-default setting.
To disable the chassis intrusion switch:
1.
Power off the system and remove the left panel as described in
Chapter 4 of this guide.
2.
Move the chassis intrusion detection jumper from pins 5-6 to pins 6-
7 to disable the alarm switch.
3.
Reinstall the side cover for your safety, and connect the power cord
to the system.
4.
Power on the system on, and wait for POST to complete.
5.
Run the SSU to configure the system.
BMC Forced Update Mode
!
CAUTION
Leave BMC Forced Update Mode jumper at factory-default
setting:
Setting this jumper incorrectly will prevent the system from
booting. Programming
should only be done
by a technically qualified
person. Contact your dealer or sales representative for more
information.