1. Installing Internal Optional Devices
Express5800/T110f-S User’s Guide
83
Chapter 2 Preparations
Install a 2.5-inch HDD cage in the server by using the following procedure.
1. Refer
to
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations.
2. While
referring
to
Chapter 2 (1.4 Removing the Side Cover
and
1.5 Removing the Front Bezel
,
remove the side cover and front bezel.
3.
Set the jumper for the backplane board installed in
the HDD cage. The jumper setting when the
onboard SATA Controller (LSI Embedded
MegaRAID) is used differs from that when the
optional RAID Controller is used. For details, refer to
1.9 Use of Internal Hard Disk Drives in the RAID
System
.
4.
Mount the rollers that come with the HDD cage on
the grooves inside the HDD bay (10 places).
5.
Insert the HDD cage into the HDD bay. The
indication of "C side" must face upward. Do not
push the HDD cage to the end, because you need
to connect cables later.