Troubleshooting 8-7
Power Supply Lamps
(hot-swap power supply model only)
The power supply on the rear of the server has two lamps.
NOTE:
The server equipped with an optional power unit can continue
the operation with the normal power unit if the other power unit is
defected (redundant function). The defected power unit can be
replaced with a new one in the hot-swap mode without power
interruption.
Power Supply LEDs
Power supply condition
LED #1 (Power) Green
LED #2 (FAIL) Amber
No AC power to all PSU
OFF
OFF
No AC power to this PSU only or power supply
failure or current limit
OFF
ON
AC present / only standby output ON
Blink green
OFF
Power supply DC outputs ON and OK
Green
OFF