1. POST Error Message
Express5800/R120f-1E Maintenance Guide
188
Chapter 3 Appendix
Error Message
Cause
Solution
C10C
BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C10D
Internal Use Area of BMC FRU
corrupted.
An illegality was detected in FRU
containing the device information.
C10E
BMC SDR Repository empty.
An error was detected on BMC
SDR.
C10F
IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C110
BMC FRU device failure.
An error was detected in FRU that
contains device information.
C111
BMC SDR Repository failure.
Failure was detected in SROM that
stores the SDR.
C112
BMC SEL device failure.
Device failure was detected in BMC
SEL.
C113
BMC RAM test error.
An error was detected in BMC
RAM.
C114
BMC Fatal hardware error.
A hardware error was detected in
BMC.
C115
Management controller
not responding
Management controller does not
respond.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
C116
Private I2C bus not
responding.
Private I2C bus does not respond.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C117
BMC internal exception
BMC internal error was detected.
C118
BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119
SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A
SEL corrupt.
BMC error or illegal system event
log data was detected.
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
installed.
Contact your sales representative.
C11C
BMC Mezzanine partition is
invalid.
A format error was detected in BMC
Mezzanine card.
C11D
BMC is in Forced Boot Mode.
Detected that BMC is in Forced
Boot Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.
C11E
Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Unplug the power cord, wait for 30 seconds,
and restart the server. If the same error is
detected repeatedly, contact your sales
representative.
C11F
Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.
C120
BMC Runtime FW corrupted.
An error occurred on BMC Runtime
FW.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server. If the
same error is detected again, contact your
sales representative.
C121
BMC Force Update FW corrupted.
An error occurred on BMC Force
Update FW.
C122
BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123
BMC eMMC inaccessible.
Failed to access to BMC eMMC.
C125
BMC eMMC mode error.
BMC eMMC mode error
C126
BMC eMMC partition corrupted.
An error occurred on BMC eMMC
partition.
C127
BMC eMMC format corrupted.
A format error occurred on BMC
eMMC.
C128
BMC is in Update Mode.
BMC is in update mode.
C300
Out-of-band setup
configuration failure
An error was detected while
accessing BMC Mezzanine card.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.