1. POST Error Message
Express5800/R120f-1E Maintenance Guide
187
Chapter 3 Appendix
Error Message
Cause
Solution
C061
1st SMBus device Error
detected.
An error was detected on 1st SM
Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd SM
Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd SM
Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th SM
Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th SM
Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th SM
Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th SM
Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th SM
Bus.
Contact your sales representative.
C101
BMC Memory Test
Failed.
An error was detected on BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
An error was detected while
accessing BMC.
C105
BMC SEL area full.
There is not enough space to store
the system event log.
Run Offline Tools (
Chapter 1, 9. Offline Tools
)
and clear the event logs.