5. RAID System Configuration
Express5800/R120f-1E Maintenance Guide
135
Chapter 2 Useful Features
5.5
Menu Tree of UEFI Mode
Menu
Value
Descriptions
Controller Management
> View Controller Information
Display of the RAID controller information
Controller Marketing Name
LSI Embedded MegaRAID
Name of the RAID controller
Display may differ due to the restrictions for the
number of digits in the display depending on the
server.
Serial Number
none
Serial number of the RAID controller
PCI ID
Device-dependent
PCI ID of the RAID controller
Host Interface
PCI-E
Host interface
Device Port Count
Device-dependent
Number of ports
PCI Slot Number
Integrated
PCI slot number of the RAID controller
Drive Count
Device-dependent
Number of Physical Drives
Virtual Drive Count
Number of Virtual Drives
Encryption Capable
No
Encryption setting
Minimum Stripe Size
64 KB
Minimum stripe size
Maximum Stripe Size
64 KB
Maximum stripe size
Driver Version
UEFI driver version
BIOS Version
UEFI BIOS version
> Change Controller Properties
Change of the parameter for the RAID controller
Apply Changes
Reflecting the change
Set Factory Defaults
Setting to the default value
Set Boot Device
Setting of the Virtual Drive to start up the OS
Rebuild Rate
30
Ratio of the Rebuild IO (30%)
Background Initialization (BGI) Rate
30
Ratio of the Background Initialize IO (30%)
Consistency Check Rate
30
Ratio of the consistency check IO (30%)
Disk Coercion
1 GB
Forcibly pack physical drives of different size
Disk WC
Disable
Setting of the physical drive caching.
The recommended setting is
Enable
.
Read Ahead
Enable
Read ahead setting
Auto Rebuild
Enable
Automatic Rebuild setting
Auto Resume
Enable
Setting whether or not to resume the process
automatically if the system is rebooted during
Initialize, Rebuild, or consistency check.
> Clear Configuration
Clearing the RAID Configuration