1. Installing Internal Optional Devices
Express5800/R120e-1M User’s Guide
93
Chapter 2 Preparations
8.
Secure the RAID Controller bracket with two screws you have removed in Step 5.
9.
Disconnect SAS/SATA cable from SATA connector on motherboard.
9-1. When four or less hard disk drives are installed:
Connect SAS/SATA cable removed in Step 9 to connector (Ports 0-3) on RAID Controller.
9-2. When five or more hard disk drives are installed:
Connect SAS/SATA cable removed in Step 9 to connector (Ports 0-3) on RAID Controller.
Connect SAS/SATA cable provided with the server to connector (Ports 4-7) on RAID Controller.
Remove a single screw from server chassis, and remove battery tray for RAID Controller.
Connect another end of SAS/SATA cable that has been connected to connector (Ports 4-7) on
RAID Controller, to the connector on backplane.
Secure the battery tray for RAID Controller with a single screw.
10. Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
(2)
When using optional RAID Controller (N8103-161/168)
See
Chapter 2 (1.14.4 Installing FBU)
.