1. Installing Internal Optional Devices
Express5800/R120e-1M User’s Guide
87
Chapter 2 Preparations
1.13.2
Supported boards and available slots
The following tables list supported boards and slots available for them. For details of the features of each
board, see the manual supplied with it.
Tips
•
Different boards mounted on the same bus operate at the lower frequency.
•
When the operation performance of a PCI card is higher than the PCI slot on the
server, the PCI card operates with the performance of the PCI slot on the
server.
(1)
Standard riser cards
Slot number
PCIe 3.0
#1A
PCIe 3.0
#1B
PCIe 3.0
#1C
PCIe 3.0
#1D
PCI slot
performance*1
x8 lane
x16 lane
x8 lane
Transfer bandwidth
(per lane) *1
8Gb/s
Slot size
Dedicated
to RAID
Controller
Full height
Low
profile
Dedicated
to LAN
riser card
PCI card type *2
x8 socket
x16 socket
x8 socket
Model
name
Product
name
Available card size
Dedicated
to RAID
Controller
Up to 220 mm
Dedicated
to LAN
riser card
Remarks
N8103-172 RAID
Controller
(512MB, RAID 0/1)
[PCI Express 3.0(x8)]
○
-
-
-
N8103-173 RAID
Controller
(512MB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
○
-
-
-
N8103-174 RAID
Controller
(1GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
○
-
-
-
Dedicated to connecting
internal disks.
An extra battery
[N8103-153] can be
mounted.
N8103-168 RAID
Controller
(1GB, RAID 0/1/5/6)
[PCI EXPRESS 3.0(x8)]
-
○
○
-
Dedicated to connecting
internal disks.
FBU is factory installed.
Cannot be installed
together with
N8103-172/173/174.
N8103-161 RAID
Controller
(1GB, RAID 0/1/5/6)
[PCI EXPRESS 2.0(x8)]
-
○
○
-
Dedicated to connecting
external devices..
FBU is factory installed.
Up to two extra battery
and/or FBU can be
installed.