1. Installing Internal Optional Devices
Express5800/R120e-1M User’s Guide
80
Chapter 2 Preparations
4.
Remove a single screw and remove battery
tray for RAID Controller.
5.
Connect a cable that comes with extra
battery to the extra battery.
When connecting the cable, pay attention to
the shape of connector, and align the
connector on extra battery with black marking
on battery control cable.
6.
Install the additional battery to the battery
tray by using 3 screws.
The installation position of the battery
depends on installed RAID Controller. See
the figure on the right.
Install N8103-162 additional battery to the
position for PCI slot #1 or #1C.
PCI #1B
または
#1C
搭載
RAID
コントローラ用
バッテリ取り付け位置
PCI #1A
搭載
RAID
コントローラ用
バッテリ取り付け位置
7.
Install the battery tray for RAID Controller
using a single screw removed in Step 4.
8.
Remove the two screws from RAID
Controller, and remove PCI bracket.
9.
Connect the cable of extra battery to RAID
Controller.
Align the connector on battery control cable
with the black making on RAID Controller,
then connect the battery control cable.
Attach the battery for
RAID Controller installed
in PCI slot #1B or #1C
Attach the battery for
RAID Controller installed
in PCI slot #1A