8-Slot Cabinet (P/N 80001)
●
Eight (8) Universal Slots
●
A typical system configuration is
40 lines x 80 extensions (line and exten-
sion maximums are limited by load fac-
tor and slot availability)
●
Wall mountable
●
On/Off switch
●
Installer-friendly design
●
Minimum space requirement
●
Light in weight
●
PCB’s must all be the “A” versions (example: 80021A)
8-Slot Cabinet Default PCB Location (U-Slot Software)
If you need to change the default PCB location:
●
Use 9902 - Slot Control to reconfigure your PCBs.
Refer to the system’s Software Manual for more.
With your U-Slot system’s default software:
●
All trunks are loop start DTMF.
Use 1001 - Trunk Circuit Type to change this assignment.
●
All extensions are 22-Button Display models.
Use 1801 - Extension Circuit Type if you need to change this
assignment.
Power Supply
Power Supply (if required)
Power Supply (if required)
CPU
16DSTU PCB (300-315)
80000 - 59
P/N 80005A
P/N 80005A
P/N 80005A
P/N 80021A
P/N 80025A
Default Configuration:
24 trunks x 80 extensions
(Note: This configuration
requires 3 power supplies.)