4-Slot Cabinet Default Setup with U-Slot Software and
CPU P/N 80025
If you need to change the default PCB location:
●
Use 9902 - Slot Control to reconfigure your PCBs.
Refer to Using Program 9902 in DS2000 to Add or Delete PCBs
on page 133 and the system’s Software Manual for more.
With your U-Slot system’s default software:
●
All trunks are loop start DTMF.
Use 1001 - Trunk Circuit Type to change this assignment.
●
All extensions are 22-Button Display models.
Use 1801 - Extension Circuit Type if you need to change this
assignment.
●
Trunks 1-24 ring on line keys 1-24.
Use User Programmable Features code #RAL or 1805 - Ring
Assignments to customize ringing.
●
Extension users can press ICM and dial 9 for an outside line. Line Dial-Up
and Direct Trunk Access are disabled.
Refer to the Central Office Calls, Placing feature in your Software
Manual for more.
Power Supply
CPU
16DSTU (300-315)
16DSTU (316-331)
8ATRU (1-8)
8ATRU (9-16)
80000 - 58
P/N 80005/A
P/N 80025
P/N 80021/A
P/N 80021/A
P/N 80011/A Ext. 401-408
P/N 80011/A Ext. 409-416
Default Configuration:
16 trunks x 32 extensions