![background image](http://html1.mh-extra.com/html/nec/ds1000/ds1000_correspondence-course-workbook_3847435141.webp)
DS1000/2000 Correspondence Course
System Programming
NEC America
DS1000/2000 Workbook
◆
141
18. Enter the extension’s Access Level (0-5) +
VOL
▲
OR
Press
VOL
▲
to leave the current entry unchanged
The previously programmed value displays.
19. Enter the extension’s overflow destination (300-395) +
VOL
▲
OR
Press
VOL
▲
to leave the current entry unchanged
The previously programmed value displays.
20. Enter the overflow condition for Intercom calls (0 = no overflow, 1 = busy, 2 =
ring, 3 = delay) +
VOL
▲
OR
Press
VOL
▲
to leave the current entry unchanged
The previously programmed value displays.
21. Enter the overflow condition for trunk calls (0 = no overflow, 1 = busy, 2 =
ring, 3 = delay) +
VOL
▲
OR
Press
VOL
▲
to leave the current entry unchanged
The previously programmed value displays.
22. Enter the overflow condition for DID calls (0 = no overflow, 1 = busy, 2 = ring,
3 = delay) +
VOL
▲
OR
Press
VOL
▲
to leave the current entry unchanged
The previously programmed value displays.
23. Enter the overflow condition for tie line calls (0 = no overflow, 1 = busy, 2 =
ring, 3 = delay) +
VOL
▲
OR
Press
VOL
▲
to go back to the first option for this port.
The previously programmed value displays.
24. Press
CONF
to select another station port to program.
OR
Press
CONF
twice to exit this program.
1801: STATION #nnn
OVRFLW EXT?nnn
1801: STATION #nnn
ICM OVRFLW B-R-D?n
1801: STATION #nnn
CO OVRFLW B-R-D?n
1801: STATION #nnn
DID OVRFLW B-R-D?n
1801: STATION #nnn
E&M OVRFLW B-R-D?n
1801: STATION #nnn
PT TYP?n