28
N°
PROTECTION
FUSE TYPE
1
Main power supply (IEC socket)
only GOLD series
40A blade fuse
2
Starter battery power line (pin n°3)
70A blade fuse
3
Aux line (pin n°5) non for
PLUS 12-24 and GOLD 12-24 models
40A blade fuse
4
Out line (pin n°6)
25A blade fuse
5
Out line (pin n°6)
25A blade fuse
6
Solar panel line (pin n°7)
non for 24V output models
25A blade fuse
7
Main power supply (IEC socket)
only GOLD series
10A glass fuse
Type 5x20
NOTE
• All the connection pins you can find in the upper table
are explained at page 14 chapter 7: connections.
• Fuses 4 and 5 are connected in parallel and they are
connected both to pin n°6.
• By replacing the fuses, the
POWER
SERVICE
will perform
an automatic restart.
• In case of further additional faults, contact the NDS
energy service center promptly.
7
10A
GLASS
FUSE