POWER SUPPLY FROM SOLAR PANEL
If the following situations occur:
• I or D + signal not active,
• Solar panel illuminated by sunlight with AN OPEN-
CIRCUIT voltage higher than 16V,
The
POWER
SERVICE
starts charging using the
integrated solar regulator with PWM technology;
charging phases are the same as those provided by the
alternator and by an external mains supply.
the device stops charging using the solar controller
when the panel voltage becomes lower than the leisure
battery (there is not enough light to sustain a charging
current).
POWER SUPPLY FROM 230V MAINS CONNECTION
(GOLD SERIES ONLY)
If the i or D+ signal is not active, and the power
supply is connected and active, the:
POWER
SERVICE
GOLD gives priority to the mains power supply and
stops using the solar panel.
The power source is selected by power priority, as
below:
1. Alternator.
2. Mains Power Supply (GOLD only).
3. Solar Panel.
The charging source used will be displayed by the
relevant LED.
8