Diagnostics
WorldMark 4300 Server Management Product Manual
B-11
No SMB Icon Shown Under Server
Possible Causes
•
SMB proxy not running
User Troubleshooting Procedure
•
See information in “Could Not Auto-discover Server Under LANDesk”
Services Troubleshooting Procedure
•
Same as above
Frequent Time-outs Seen When Retrieving Data
Possible Causes
•
Communications parameters not configured appropriately on console
User Troubleshooting Procedure
•
Increase the Communications timeout and retries options using the LANDesk Configure >
Communications dialog.
Services Troubleshooting Procedure
•
Telnet to the server and check its utilization
•
ping the server to check the response time
Historian Graphs Do Not Display
Possible Causes
•
Historian process have failed
•
Communications Timeouts value is too low
•
Historian data file is corrupted
•
Console and server incompatibility in data messages
User Troubleshooting Procedure
•
Verify appropriate console and server versions are compatible
•
Increase the Communications Timeouts/Retry option and retry History graph display
•
On UNIX server, verify all ldsm process, particularly Historian, are still running
•
Stop and restart the ldsm server process, then redisplay the History graph
•
Check the UNIX Server Manager log for problems with the Historian process
Summary of Contents for WorldMark 4300
Page 1: ...BD20 1398 B000 12 97 WorldMark 4300 Server Management Product Manual Release 2 0...
Page 6: ...Contents iv Table of Contents...
Page 10: ...Preface viii Preface...
Page 14: ...Monitored Controlled Attributes 1 4 Overview...
Page 50: ...Working With Event Actions 2 36 User Interface...
Page 66: ...Chassis Events A 10 SMB Event Code Tables...
Page 96: ...LANDesk UNIX Server Troubleshooting B 30 Troubleshooting...
Page 100: ...Index Index 4 WorldMark 4300 Server Management Product Manual...