![Nautel XR6 Operation And Maintenance Manual Download Page 70](http://html2.mh-extra.com/html/nautel/xr6/xr6_operation-and-maintenance-manual_3623858070.webp)
XR6/XR3 Operations and Maintenance Manual
Routine maintenance
Issue 3.1 2013-03-14
Page 4-5
Procedure
Perform the following steps to test the lightning protection systems:
1. Test the continuity between ground available at your lightning arrestor and ground available
on various pieces of equipment connected to the transmitter. Ensure that there is no
resistance (0 ohms).
2. Physically inspect the lightning arrestor to ensure that all connections are tight. Also look for
any sign of scoring or burning (indications of possible damage from earlier lightning strikes).
3. Using binoculars, visually inspect the hardware on the tower. Look for charred, broken or
frayed connections and corrosion.