XR6/XR3 Operations and Maintenance Manual
Operating the transmitter
Page 2-28
Issue 3.1 2013-03-14
Figure 2.22: High Power Lockout page
To set the high power lockout limit, perform the following steps (see
1. Use the
Up
and
Down
buttons to select
High Power Lockout
. Press the
Edit
button, then
press the
Up
and
Down
buttons, to select
Disabled
. Press the
Save
button to save your
setting. (Pressing the
Cancel
button discards your changes.)
2. Set the transmitter’s output power to the desired lockout power level. Note the
Current
Carrier Reference
value carrier reference value, which corresponds to the transmitter’s
output power.
3. Use the
Up
and
Down
buttons to select
High Pwr Lock Carrier Limit
. This value represents
the carrier reference (output power) limit for the high power lockout feature. When the high
power lockout feature is activated, the transmitter power cannot increase beyond this limit.
Press the
Edit
button, then press the
Up
and
Down
buttons to change the value to the same
value as the
Current Carrier Reference
. Press the
Save
button to save your setting. (Pressing
the
Cancel
button discards your changes.)
4. Use the
Up
and
Down
buttons to select
High Power Lockout
. Press the
Edit
button, then
press the
Up
and
Down
buttons, to select
Enabled
. Press the
Save
button to save your
setting. (Pressing the
Cancel
button discards your changes.)
5. Apply an active input to the remote
Preset 6
control (J2-22) on the remote interface PWB
(A2A6) to activate the high power lockout feature.
Note: When the high power lockout feature is enabled, the remote Preset 6 control input (J2-22) of
the remote interface PWB (A2A6) is used to activate and de-activate the lockout. There is no
remote control of preset 6 while high power lockout is enabled.
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
High Power Lockout: Enabled
High Pwr Lock Carrier Limit: 45
(Current Carrier Reference: 32
Use the arrow keys to select a value to
change. Press EDIT to make changes.
Edit
Back
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
High Power Lockout: Enabled
High Pwr Lock Carrier Limit: 45
(Current Carrier Reference: 32
Use the arrow keys to select a value to
change. Press EDIT to make changes.
Edit
Back
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......