XR6/XR3 OPERATIONS AND MAINTENANCE MANUAL
VERSION 3.1 2013-03-14
PAGE XV
Marking Hazards
Place warning signs close to any hazardous areas or systems (e.g., the feedline or the antenna system).
Make the signs large enough that they cannot be missed. Provide signage in all languages used in the
region. These signs are intended not only for authorized personnel, but also for emergency responders
or accidental trespassers.
Qualifying Site Personnel
Make sure that personnel who have access to the site are qualified to work around electronics and high
voltage systems.
Ac Power Protection
You should take steps to protect equipment from surges (over-voltage spikes) on the ac power lines.
Surges may occur during thunderstorms, or because of malfunctions in the electrical distribution grid.
Surge suppressors and ac power conditioners can prevent serious damage to your on-site equipment,
including the transmitter.
RF Protection
Transmitters and their antenna systems create intense radio frequency fields at the transmitter site,
particularly near the feedline, antenna and tower. At some sites, these fields may cause biological
effects, including the heating of body tissues. Intense fields can also create dangerous high voltages on
ungrounded, conductive surfaces and objects. At certain points where high voltage conductors come
close to grounded conductors (e.g., at feedline junctions or on the tower), dangerous electrical arcing or
overs can occur. It is very important that you take the following steps to prevent damage to equipment
or personnel due to RF fields:
Use safety interlocks to de-energize transmitters if personnel open doors or panels accessing high
field areas
Place warning signs in any locations where high fields can occur
Train personnel about the short-term and long-term hazards of RF radiation
Physically block access to the area around the antenna system, feedline and tower
Ground all exposed conductive surfaces or objects in high field areas
The RF connection to the transmitter output can be a serious safety hazard. Connect a 50
Ω
test load
during installation and commissioning. It is recommended that a switch be used to automatically
connect the transmitter to the antenna system without human contact with the transmitting
conductors.
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......