XR6/XR3 Operations and Maintenance Manual
Using the event log
Issue 3.1 2013-03-14
Page 3-7
Event log messages
Table 3.1: Event messages
Event Log Messages
Explanation
Softstart Complete
B+ relays have closed.
Cmd. Auto Exciter
Automatic Exciter changeovers have been enabled.
Cmd. Man Exciter
Automatic Exciter changeovers have been disabled.
Comd. Power Preset (1-6)
Preset # (1-6) has been selected.
Command Auto Power
Automatic Preset changes using the Preset Scheduler have been
enabled.
Command Manual Power
Automatic Preset changes using the Preset Scheduler have been
disabled.
Command Exciter A
Changeover to Exciter A.
Command Exciter B
Changeover to Exciter B.
Command LOCAL
Remote control has been disabled. Local control is in effect.
Command REMOTE
Remote control has been enabled. Local control is limited.
Command RF OFF
RF Off has been ordered.
Command RF ON
RF On has been ordered.
EEPROM Restore Fail
There has been a power failure, and the backup settings have
not been restored due to a settings corruption.
Return to normal
All shutbacks and cutback conditions have been cleared.
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......