XR6/XR3 Operations and Maintenance Manual
Operating the transmitter
Page 2-26
Issue 3.1 2013-03-14
To view the
Calibrate B+ Thresholds and Switching Points
page, select
Settings
from the
MAIN
MENU
page (
Hardware Settings
from the
, then select
B+ Switching
.
Figure 2.20: Calibrate B+ Thresholds and Switching Points (3-phase ac power)
Figure 2.21: Calibrate B+ Thresholds and Switching Points (1-phase ac power)
Calibrate B+ threshold.
If required, you can use the
Calibrate B+ Thresholds
page (
or
) to adjust the thresholds used to disconnect and reconnect the B+ dc voltage to the
XR6/XR3 transmitter.
To calibrate the B+ thresholds, perform the following steps (see
1. Use the
Up
and
Down
buttons to select the appropriate
Discon.
(disconnect) level, noting it
is in the left-hand
B+ Thresholds
column. Press the
Edit
button, then press the
Up
and
Down
buttons, to adjust the threshold (in volts) as desired. Press the
Save
button to save
your calibration. (Pressing the
Cancel
button discards your changes.)
CAUTION:
Do not calibrate B+ thresholds unless specifically instructed by Nautel personnel.
Decreasing the Recon. (reconnect) level can damage the transmitter.
10:18 0.00kW M-1 B+2 PM:A Man Ex:A Man
Car. Ref. Limit B+ Thresholds
B+ Lvl Minimum Maximum
Discon. Recon.
88 167 250 V 265 V
52 89
155 V 165 V
1
0 0 0 V 0 V
Edit
Carrier Ref = 0 PDM A = 0.00 B = 0.00
3
2
Edit
Back
10:18 0.00kW M-1 B+2 PM:A Man Ex:A Man
Car. Ref. Limit B+ Thresholds
B+ Lvl Minimum Maximum
Discon. Recon.
88 167 250 V 265 V
52 89
155 V 165 V
1
0 0 0 V 0 V
Edit
Carrier Ref = 0 PDM A = 0.00 B = 0.00
3
2
Edit
Back
XR3 uses 2 B+ levels
XR6 uses 3 B+ levels
(0 and 3; level 2 line
(0, 2 and 3)
Scroll down to
view B+ level 0
also displays ‘0’s
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Car. Ref. Limit B+ Thresholds
B+ Lvl Minimum Maximum
Discon. Recon.
96 113 174 V 185 V
54 97
156 V 165 V
1
33 55 91 V 97 V
Edit
Carrier Ref = 0 PDM A = 0.00 B = 0.00
3
2
Edit
Back
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Car. Ref. Limit B+ Thresholds
B+ Lvl Minimum Maximum
Discon. Recon.
96 113 174 V 185 V
54 97
156 V 165 V
1
33 55 91 V 97 V
Edit
Carrier Ref = 0 PDM A = 0.00 B = 0.00
3
2
Edit
Back
Scroll down to
view B+ level 0
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......