![Nautel XR6 Operation And Maintenance Manual Download Page 33](http://html2.mh-extra.com/html/nautel/xr6/xr6_operation-and-maintenance-manual_3623858033.webp)
XR6/XR3 Operations and Maintenance Manual
Operating the transmitter
Page 2-8
Issue 3.1 2013-03-14
Controlling power modules
Figure 2.3: Power Modules page
On this page the user can perform a power module reset by pressing the
PM Reset
button.
The user can set the
Transfer Mode
to
Auto
or
Manual
. In
Auto
mode, if the enabled power modules
fail, the transmitter will perform a power module changeover to replace the failed power module with
the designated standby power module.
The user can select which power module is active and which is the standby by editing the
Desired
Config
option. The possible combinations are:
•
Module A enabled, with module B on standby.
•
Module B enabled, with module A on standby.
The
Current Status
line displays the currently-enabled module(s). If no power module is currently
enabled, an unusual situation, then the message
None enabled
will be displayed.
Press the
Back
button to return to the
Main Menu
page.
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Transfer Mode: Manual
Desired Config: A enabled, B standby
Current Status: A enabled
Use Arrow Keys to Select a value.
Press EDIT to modify the value.
PM Reset
Edit
Back
10:18 0.00kW M-1 B+1 PM:A Man Ex:A Man
Transfer Mode: Manual
Desired Config: A enabled, B standby
Current Status: A enabled
Use Arrow Keys to Select a value.
Press EDIT to modify the value.
PM Reset
Edit
Back
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......