Wiring/Connection Information for Soda Load and Dry Cooler Wiring Kits
Issue 0.3
Not to Scale
Figure 2-10
Page 2-32
VIEW A - SODA LOAD CONTROL BOX - CABLE HOLE LAYOUT
Install HAA93
Route WG58 control
wiring and connect as
shown below
Install HAA90
Route WG54 power
wiring and connect as
shown below
Install HAA67
Route WE32 interlock
wiring and connect as
shown below
VIEW E - DRY COOLER ELECTRICAL ENCLOSURE LAYOUT
TB1
SEE APPENDIX B FOR DETAILED ELECTRICAL SCHEMATICS OF THE SODA
LOAD CONTROL BOX AND THE DRY COOLER ELECTRICAL ENCLOSURE
CONTROL/INTERLOCK WIRING CONNECTIONS
FROM TO
WIRE
REMARKS
SL-T2-3
4-port switch
control box
WE32 Interlock
SL-T2-4
4-port switch
control box
WE32 Interlock
SL-T2-5 DC-005
WG58
M1/M2
enable
SL-T2-6 DC-008
WG58
M3/M4
enable
SL-T2-7 DC-011
WG58
M5/M6
enable
SL-T2-8
DC-003 (ac com)
WG58
Ac Common
SL-T2-9
DC-002 (24 ac)
WG58
24 V ac
SL = Soda Load; DC = Dry Cooler
L1 L2 L3 Gnd
VIEW B - SODA LOAD CONTROL BOX - AC AND CONTROL CONNECTIONS
VIEW C - CONTROL/INTERLOCK
VIEW D - 400 V AC, 3-PH INPUT
T2
HAA93 Teck
connector
AC DISCONNECT
SWITCH (SA80)
6 AWG, 3-cond
Teck 90 and # 8
gnd wire (WG54)
400 V ac, 3-ph
from breaker
DRY COOLER
(UP137, UP138)
NOTE:
wire entry holes must
be punched by the user.
Should be the same size as
holes used in soda load for
HAA90 and HAA93
connectors.
AC DISCONNECT
SWITCH (SA80)
400 V ac, 3-ph
from breaker
NOTES:
Install ac disconnect switches
close to load and dry cooler
Remove appropriate knockouts
in bottom of switch to install
two HAA90 Teck connectors.
Manual lockout switch offers ac
disconnect option (incorporate
into site's formal lockout
procedure)
HAA90 Teck
connector
(qty 4)
HAA90 Teck
connector
(qty 4)
HAA67
Grommet
WE32 2-conductor
cable for interlock
connection; route
other end to 4-port
switch's control box
HAA93 Teck
connector
WG58 6-conductor
cable for control wiring
(see Views B through E
and wiring table for detail)
L1
L2
L3
Gnd
L1
L2
L3
Gnd
SODA LOAD
(UP133, UP134)
SODA LOAD
CONTROL BOX
(see wire entry holes
in View A)
Summary of Contents for NX200
Page 2: ......
Page 12: ......
Page 16: ......
Page 21: ......
Page 24: ......
Page 26: ......
Page 30: ......
Page 49: ......
Page 50: ...Antenna Tuning Unit Ground Switch Views Issue 0 3 Not to Scale Figure 2 11 Page 2 35 ...
Page 51: ...Antenna Tuning Unit Safety Screen Views Issue 0 3 Not to Scale Figure 2 12 Page 2 36 ...
Page 55: ......
Page 66: ......
Page 70: ...Trip Circuit for Breaker Panel s Main Breaker Issue 0 3 Not to Scale Figure 2 24 Page 2 56 ...
Page 74: ......
Page 80: ......
Page 97: ......