background image

Model NV-EC1701
EoC Ethernet over Coax Transceiver

with PoE, PoE+, or High Power PoE

Page 1 of 14

Complete Installation Guide

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat regis-
ters, stoves or other apparatus (including DVRs) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wider blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched particu-
larly at plugs, convenience receptacles, and the point where they exit
from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12)  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is
required when the apparatus has been damaged in any way, such as
a power supply cord or plug is damaged, liquid has been spilled, or
objects  have  fallen  into  the  apparatus,  the  apparatus  has  been
exposed to rain or moisture, does not operate normally, or has been
dropped. This installation should be made by a qualified service per-
son and should conform to all local codes.

13) BNC Connection: the installation shall be in accordance with the
applicable  provisions  of  the  National  Electrical  Code ANSI/NFPA  70,
Article 800.90 and Canadial Electrical Code Part 1, Section 60-504.

14) RJ45 PoE connection: to be connected only to networks or circuits
that are not routed to outside plant or building.

This installation should be made by a qualified service person and

should conform to all local codes.

WARNING - Do not install the unit in an environment where the

operating ambient temperature exceeds 185° F (85° C). The ventila-
tion should not be impeded by covering the unit with items, such as
newspapers, table-cloths, curtains, etc. No naked flame sources, such
as lighted candles should be placed on the apparatus.

WARNING - Do not interconnect multiple outputs. Never

use more than two power supplies within a network system.

WARNING - The apparatus shall not be exposed to dripping or

splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.

WARNING - Use only a Certified power cord and plug (coupler /

mains) assemblies for location installed.

WARNING - Power cord is regarded as main disconnect.

WARNING  -  The  appliance  coupler  (power  cord/mains)  shall

remain readily operable.

WARNING - For safety, never put NVT signals in the same con-

duit as high-voltage wiring.

This product is intended to be supplied by a certified power source
marked “Class 2” or “LPS” and rated 48-56 VDC, minimum 840mA,
which may or may not be provided with the product.

Power supplies, when provided, are external inline, with an IEC380-
C14 power inlet and 6 ft (1.8 m) line-cord. Input Voltage is 100 ~240
VAC  50-60  Hz. A  molded  P1J  5.5  mm  barrel  connector  provides  a
Class 2 (SELV) 48-56 VDC regulated output. Line cord UL approved
type  SPT-2,  SVT,  or  SJT,  18/3 AWG  Min.  300VAC,  60°  C  Max.  15ft
(4.5m)  long.  One  end  with  IEC380-C13  appliance  coupler  and  the
other end with NEMA 1015P or equivalent for country.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER OR
BACK. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for NV-EC1701

Page 1: ...on to be connected only to networks or circuits that are not routed to outside plant or building This installation should be made by a qualified service person and should conform to all local codes WARNING Do not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers tab...

Page 2: ... Camera System Kits Limited lifetime warranty The NVT Model NV EC1701 Ethernet over Coax EoC Transceiver is a compact media converter that allows 10 100 BaseT Ethernet and PoE power to be transmitted using coax cable These devices are often used in legacy installations where existing cable is re deployed as part of an upgrade to IP cameras 48 or 56 VDC class 2 power is delivered to one transceiver...

Page 3: ...ill find each other and establish encrypted communication In about 10 seconds the blue Power LEDs on both transceivers will return to a steady on condition indicating a successful Join Step Four Adding Transceivers if required Disconnect transceiver 2 and replace it with a new un joined transceiver 3 or 4 or 5 Repeat steps two and three to add additional transceivers to the same Network Group Step...

Page 4: ...Connecting the Control room End Install a second NV EC1701 at the control room end of the coax cable If rack mounting is desired use the NV RMEC16 tray which supports up to four NV EC1701 transceivers which together can support up to 16 cameras Connect the coax cable to the BNC jack on the NV EC1701 Connect a class 2 SELV 48V or 56VDC power supply to the power jack on the NV EC1701 This will provi...

Page 5: ...nd some RJ45 ports for IP cameras The RJ45 video in port is the con nection point for the NV EC1701 See figure 2 By deploying a Hybrid DVR with its dedicated IP camera port s the network is robust and secure with none of the traffic hack ing or virus vulnerabilities associated with PC like hardware on an open LAN Depending on the Hybrid DVR more than one camera may be connected to its IP camera po...

Page 6: ...ging critical for their day to day operations and not managed by the same group that manages their security IP video can often consume large amounts of bandwidth which may or may not be compatible with existing IT traffic Security Considerations Most surveillance systems are installed specifically to protect against breaches in security A shared LAN provides potential opportunities for unauthorize...

Page 7: ...ed by the control room NV EC1701 For fault safety never use more than two power supplies within a network BNC T Figure 4 Alternate Power Supply Location Power Supply NV EC1701 NV EC1701 Model NV EC1701 www nvt com 1 650 462 8100 44 0 208 977 6614 Ethernet over Coax Transceiver Model NV EC1701 www nvt com 1 650 462 8100 44 0 208 977 6614 Ethernet over Coax Transceiver NVR LAN WAN IP Camera Door Acc...

Page 8: ...deliver DC power and separately to deliver high frequency data signals The graph below shows maximum power delivery when using a 48V power supply If you are using a 56V power supply your distances will be 2 6 times those shown in figure 4 If you are not delivering power to your camera or other remote device then this graph does not apply Figure 5 shows the maximum network data rate A Distance Calc...

Page 9: ...t 1 640 ft 1 968 ft 2 624 ft 3 280 ft 3 936 ft 4 920 ft 5 904 ft 6 560 ft 2 500 m 3 000 m 4 000 m 5 000 m 8 200 ft 9 840 ft 13 120 ft 16 400 ft Ethernet Aggregate Data Throughput C C C A i W W W W W W W T V T V T T A 0 0 G 5 9 U 2 U 2 U R A G G W G W W G 6 1 8 1 8 R W G W W R G 1 1 1 1 1 1 1 A W G C A T V W ir e R G 5 9 U 2 0 A W G R G 6 1 8 A W G R G 1 1 1 4 A W G There are a wide variety of wire...

Page 10: ...e than two power supplies within a network system L E D S TAT U S I N D I C AT O R S Power Blue Power On BNC Interface Green Link RJ45 Interface Green Link M E C H A N I C A L E N V I R O N M E N TA L Transceiver body dimensions 5 1 in 131mm long excluding connectors 1 3 in 33mm high 1 5 in 38mm wide Transceiver weight 5 1oz 145g Operating and storage temperature 40 F to 185 F 40 C to 85 C 20 to 8...

Page 11: ...6VDC power supply 90 watts with IEC line cord NV BNCT BNC T adaptor NV EC4BNC 1 4 BNC splitter adaptor NV PC4PR RJ45 Patch Cord 4 pair 3 1m Grey NV DPSC4 Detachable Power Supply Cord Splitter 1 4 2ft NV RMEC16 Rack mounting chassis 19 x 1U holds up to 4 NV EC1701 transceivers plus power supplies Includes NV DPSC4 Power Cord Splitter NV EC1701 and NV PS48 60W not included NV EC1701 Single transceiv...

Page 12: ...CT BNC T Adaptor 3 NV PC4PR patch cord Triple EoC Transmission System NV EC1701 KIT3 4 NV EC1701 Transceivers 1 NV PS48 60W Power Supply with IEC line cord 1 NV EC4BNC 1 4 BNC splitter adaptor 4 NV PC4PR patch cord Quadruple EoC Transmission System NV EC1701 KIT4 5 NV EC1701 Transceivers 1 NV PS48 60W Power Supply with IEC line cord 1 NV EC4BNC 1 4 BNC splitter adaptor 5 NV PC4PR patch cord Produc...

Page 13: ...le mented on a host such as a switch or router within the network Virtually all routers and most switches are equipped with an IGMP querier That host is responsible for sending IGMP queries to multicast devices and for generating an IGMP Report That report is moni tored by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers keep a state table ...

Page 14: ... of NVT any warranty for those products will cease and NVT will have no further liability as it pertains to those products NVT assumes no responsibility for damages or penalties incurred resulting from the use of this product in a manner or location other than for which it is intended NVT s liability under any warranties shall be discharged by replacing or repairing any part or parts which do not ...

Reviews: