NX25/NX15 Troubleshooting Manual
Responding to alarms
Issue 5.0 2016-05-06
Page 1-13
Controller: High RF
Drive
This alarm indicates the controller's RF Drive Duty Cycle meter
has risen above 60% for longer than 10 seconds. This alarm will
cause an exciter changeover, if automatic changeover is enabled
and the transmitter is operating on the main exciter. If there are
two exciters in the transmitter, swap exciter positions. If the alarm
follows the exciter, or there is only one exciter in the system,
replace the digital AM exciter PWB (see
). If the alarm persists, or the alarm
remains with the position, replace the control/interface PWB (see
“Control/interface PWB replacement” on page 1-60
).
Controller: Host Network
Down
This alarm indicates the transmitter is configured to have
networking enabled, but the host is indicating there is no network
connectivity. If the transmitter is not connected to a network, the
alarm can be inhibited by changing the network settings to static
IP and setting the IP address to 0.0.0.0. If the transmitter is
connected to a network, verify the network settings are configured
properly, and the network cable is connected to the correct port on
the transmitter.
Controller: Host Not
Booted
This alarm indicates that the controller has not received any
communication from the host since the last time the controller
booted (i.e., was powered up). The occurrence of this alarm is
normal for approximately one to five minutes while the host is
booting, immediately after ac power has been applied to the
transmitter. If this alarm continues to occur more than 30 minutes
after ac power has been applied to the transmitter, cycle (turn off,
then on) the ac power. If the alarm persists after 30 minutes,
replace the SBC or control/interface PWB (see
).
Controller: Host Not
Responding
This alarm indicates that the controller has not received any
communication from the host in a set period of time. The
occurrence of this alarm is normal for approximately one to five
minutes while the host is booting, immediately after ac power has
been applied to the transmitter. If this alarm continues to occur
more than 30 minutes after ac power has been applied to the
transmitter, cycle (turn off, then on) the ac power. If the alarm
persists after 30 minutes, replace the SBC or control/interface
PWB (see
“Control/interface PWB replacement” on page 1-60
).
Alarm (with Prefix)
Description and Troubleshooting Action
Summary of Contents for NX15
Page 2: ......
Page 4: ......
Page 8: ...NX25 NX15 Troubleshooting Manual Page viii Issue 5 0 2016 05 06...
Page 78: ...NX25 NX15 Troubleshooting Manual Responding to alarms Page 1 70 Issue 5 0 2016 05 06...
Page 96: ...NX25 NX15 Troubleshooting Manual Detailed Circuit Descriptions Page 2 18 Issue 5 0 2016 05 06...
Page 104: ...NX25 NX15 Troubleshooting Manual Parts Lists Page 3 8 Issue 5 0 2016 05 06...
Page 216: ...NX25 NX15 Troubleshooting Manual Wiring connector lists Page 4 12 Issue 5 0 2016 05 06...
Page 222: ...NX25 NX15 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 5 0 2016 05 06...
Page 250: ...Issue 5 0 2016 05 06 MD 1 Figure MD 1 NX15 NX25 Transmitter Front View...
Page 251: ...Issue 5 0 2016 05 06 MD 2 Figure MD 2 NX15 NX25 Transmitter Rear View...
Page 254: ...Issue 5 0 2016 05 06 MD 5 Figure MD 5 NAE96C 01 Control Exciter Panel...
Page 257: ...Issue 5 0 2016 05 06 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Page 261: ...Issue 5 0 2016 05 06 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Page 263: ...Issue 5 0 2016 05 06 MD 14 Figure MD 14 NAX243A B Distribution Assembly...
Page 265: ...Issue 5 0 2016 05 06 MD 16 Figure MD 16 NAPA34A Modulator Power Amplifier PWB Front View...
Page 267: ...Issue 5 0 2016 05 06 MD 18 Figure MD 18 Fan Tray Assembly 207 8133...
Page 268: ...Issue 5 0 2016 05 06 MD 19 Figure MD 19 Voltage Probe 207 6111...
Page 269: ...Issue 5 0 2016 05 06 MD 20 Figure MD 20 Current Probe 207 6213 04...
Page 270: ...Issue 5 0 2016 05 06 MD 21 Figure MD 21 NAFP106B 02 Directional Coupler A1 DETAIL...
Page 273: ......