NX25/NX15 Troubleshooting Manual
Responding to alarms
Page 1-2
Issue 5.0 2016-05-06
Remote troubleshooting
Remote on-air troubleshooting consists of monitoring the transmitter's radiated signal using an on-air
monitor, and observing the status of each remote fault alarm indicator. Information obtained from
these sources should enable an operator to decide whether an alarm response may be deferred to a
more convenient time, an immediate corrective action must be taken, or if a standby transmitter must
be enabled (if one is available). It is recommended that the significance of remote indications, and the
appropriate responses, be incorporated into a station's standard operating procedures. Refer to
“Identifying an alarm” on page 1-4
to determine the remedial action required for a given fault.
Local troubleshooting
Local on-air troubleshooting consists of monitoring the transmitter's integral meters and fault alarm
indicators. Analysis of this data will normally identify the type of fault, and in most cases will
determine what corrective action must be taken. Refer to
“Identifying an alarm” on page 1-4
to
determine the remedial action required for a given fault.
The power amplifier stage contains an integral modular reserve (IMR) feature. This feature permits
the transmitter to operate at a reduced RF output level when a malfunction occurs in one of its power
modules. Station operating procedures will dictate whether a reduced RF output level is acceptable.
When a reduced RF output level can be tolerated, replacement of the defective RF power module
may be deferred to a convenient time.
A defective RF power module may be removed from the transmitter for servicing, while the
transmitter is operating, provided that the conditions in the removal instructions detailed in
“Removing an RF power module” on page 1-45
Off-air troubleshooting
Off-air troubleshooting must be performed when the replacement of a defective RF power amplifier
module, or routine on-air calibration adjustments, will not restore operation.
It is recommended that the transmitter’s output be connected to a precision 50
resistive dummy
load (rated for 1.5 times the maximum transmitter power rating) before starting off-air
troubleshooting procedures. If an appropriate dummy load is not available, troubleshooting for a
majority of faults can be performed with RF power stage turned off. The transmitter may remain
connected to its antenna system for these procedures.
NOTE:
Reduce the RF output level to a minimal value when troubleshooting faults in the power
amplifier stage while the transmitter’s RF output is connected to the antenna system.
Summary of Contents for NX15
Page 2: ......
Page 4: ......
Page 8: ...NX25 NX15 Troubleshooting Manual Page viii Issue 5 0 2016 05 06...
Page 78: ...NX25 NX15 Troubleshooting Manual Responding to alarms Page 1 70 Issue 5 0 2016 05 06...
Page 96: ...NX25 NX15 Troubleshooting Manual Detailed Circuit Descriptions Page 2 18 Issue 5 0 2016 05 06...
Page 104: ...NX25 NX15 Troubleshooting Manual Parts Lists Page 3 8 Issue 5 0 2016 05 06...
Page 216: ...NX25 NX15 Troubleshooting Manual Wiring connector lists Page 4 12 Issue 5 0 2016 05 06...
Page 222: ...NX25 NX15 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 5 0 2016 05 06...
Page 250: ...Issue 5 0 2016 05 06 MD 1 Figure MD 1 NX15 NX25 Transmitter Front View...
Page 251: ...Issue 5 0 2016 05 06 MD 2 Figure MD 2 NX15 NX25 Transmitter Rear View...
Page 254: ...Issue 5 0 2016 05 06 MD 5 Figure MD 5 NAE96C 01 Control Exciter Panel...
Page 257: ...Issue 5 0 2016 05 06 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Page 261: ...Issue 5 0 2016 05 06 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Page 263: ...Issue 5 0 2016 05 06 MD 14 Figure MD 14 NAX243A B Distribution Assembly...
Page 265: ...Issue 5 0 2016 05 06 MD 16 Figure MD 16 NAPA34A Modulator Power Amplifier PWB Front View...
Page 267: ...Issue 5 0 2016 05 06 MD 18 Figure MD 18 Fan Tray Assembly 207 8133...
Page 268: ...Issue 5 0 2016 05 06 MD 19 Figure MD 19 Voltage Probe 207 6111...
Page 269: ...Issue 5 0 2016 05 06 MD 20 Figure MD 20 Current Probe 207 6213 04...
Page 270: ...Issue 5 0 2016 05 06 MD 21 Figure MD 21 NAFP106B 02 Directional Coupler A1 DETAIL...
Page 273: ......