background image

16

NARVON

6.8.2 Optionals (Timer)

The timer shown is given as an indication 

only.

The timer must be set while the main switch 

is positioned on -0- and the machine is 

unplugged.

6.8.2.1 Setting the current time

Before you start using the timer you must set the current 

date and time.

To set, turn the timer dial in the direction indicated by the 

arrow until the indicator

(A) shows the correct date; then turn the pointer (C) until 

reaching the current time

Do not:

-  turn the pointer using a tool;

-  turn the pointer in the direction opposite 

that is shown in the timer.

6.8.2.2 Operating the machine  

with the timer

In all machines equipped with a timer, the 

user must check that the selector (B) is in the 

central position   .

The machine must be started as shown in Section 6.2.

Switch   in position “I”:
-  to obtain slushy, position the timer lever in position 

 on 

the desired date and time;

-  to obtain cold drinks, position the timer lever in position 

on the desired date and time.

Switch   in position “II”: 

the timer is off and the machine works as a beverage cooler 

only.

6.8.3 Mechanical thermostat

It is possible to regulate the temperature of machines 

provided with a mechanical thermostat, when they 

operate in “cold drink” mode. To do so, simply adjust the 

refrigeration power using the potentiometer. To obtain a 

higher refrigeration power (lower product temperature) turn 

it clockwise towards higher power values.

6.8.4 Dirty filter signal
6.8.4.1 Air machines

When the machine is working in critical conditions, due to 

dirt accumulated in the condenser, the insufficient air supply 

at the condenser causes an increase of temperature at the 

cold circuit. Optionally it is possible to install a sensor that 

warns you about this situation. When it happens, a red pilot 

will flash (PR).

To reset the machine it must be disconnected, the left panel 

removed and the condenser cleaned (see Section 7.9).

Reconnect the machine and press the restart button (R) 

situated on the right panel. The red pilot light (PR) on the 

front panel will turn off.

6.8.4.2. Water machines

The machines provided with a condenser refrigerated with 

water include a pressure sensor, so that, when the pressure 

rises and reaches a safety value (factory setting) due to an 

insufficient water supply for proper refrigeration it sends a 

signal to the compressor and stops it. A red pilot light (PR) 

will light up automatically on the front panel.

When this happens, the operator should stop the machine, 

check the water connections and the water supply, turn the 

machine back on and press the pressure switch (R) to re-

establish normal operation. The pilot light will turn off when 

the machine begins to operate normally once again.

A
B
C

Fig.23

1

3

4

5

6

7

0

2

1

3

4

5

6

7

0

2

Fig.24

Summary of Contents for SLUSHY 378SM2

Page 1: ...1 NARVON NARVON SLUSHY SERVICE MANUAL READ THOROUGHLY BEFORE OPERATION UPDATED 01 2022 378SM2 DOUBLE BOWL 378SM1 SINGLE BOWL 378SM3 TRIPLE BOWL...

Page 2: ...ETY 8 3 1 General safety rules 8 3 2 Stop functions 8 3 3 Plates 8 4 HANDLING AND STORAGE 8 4 1 Packaging 9 4 2 Conveyance and handling 9 4 3 Storage 9 5 INSTALLATION 10 5 1 List of accessories provid...

Page 3: ...17 7 1 Emptying the bowls 18 7 2 Disassembling the dispensing tap 19 7 3 Removing the bowl and the lid 19 7 4 Washing and sanitizing the components 20 7 5 Reassembling the washed components 20 7 6 Ri...

Page 4: ...ng slushy machines must know how to behave in case of emergency where to find individual safety equipment and how to use it properly Persons who do not meet the above requirements must not be allowed...

Page 5: ...te safely DANGER OF ELECTROCUTION This symbol warns the personnel concerned that the operation described may result in an electric shock unless all the necessary safety precautions are taken IMPORTANT...

Page 6: ...st Freeze refrigeration system Slushy 2 FF identifies a Slushy machine with two 2 bowls and Fast Freeze refrigeration system Slushy 3 FF identifies a Slushy machine with three 3 bowls and Fast Freeze...

Page 7: ...s All Bowl mixing switch one for each bowl it is used to switch on and off the gearmotor that drives the auger for mixing the product in the respective bowl All Refrigeration system changeover switch...

Page 8: ...stances suspended in the air use the machine in a place where there is a risk of fire use the machine to dispense substances that are not compatible with the machine s specifications Before cleaning t...

Page 9: ...e packing container The WARRANTY does not cover damage caused to the machine during its conveyance and handling The Purchaser will bear the cost of repairing or replacing damaged parts 4 3 Storage Bef...

Page 10: ...he site has been duly prepared for machine installation the surface that the machine will be installed on is firm flat and solid the room is adequately lit ventilated and hygienic and an electric outl...

Page 11: ...pply when necessary If the power cord is damaged you must have it replaced either by the manufacturer or a specialized technician It is forbidden to use extension cords of any type to replace the orig...

Page 12: ...efore carrying out any operation inside the bowl 6 2 Starting a Slushy Machine For the sake of simplicity only the operation of the right bowl will be illustrated to operate the other bowls simply car...

Page 13: ...last key is pressed the setting is stored to memory and the display will show the temperature of the product in the tank ALARMS In case of probe failure the display will read A1 Programming and adjus...

Page 14: ...start it again press the key If the temperature display should not switch on again switch off the machine and contact your nearest assistance center Important While using the machine the temperature...

Page 15: ...nitizer solution around the spigot area and on the spigot itself alternatively wash with a clean cloth and sanitizer or Dispense a small amount of the product from the spigot before dispensing the ser...

Page 16: ...sing the potentiometer To obtain a higher refrigeration power lower product temperature turn it clockwise towards higher power values 6 8 4 Dirty filter signal 6 8 4 1 Air machines When the machine is...

Page 17: ...instructions wear protection accident proof gloves do not use solvents or inflammable materials do not use abrasive and or metal sponges to clean the machine and its components take care to avoid disp...

Page 18: ...t prevent the build up of germs and mold in the event of inadequate cleaning It is forbidden to clean or service the machine when it is plugged in and the main switch is positioned on 1 7 1 Emptying t...

Page 19: ...ll upwards as shown These components may be placed in a basin containing hot water approx 50 C 122 F they must later be treated as described in Section 7 4 Never disassemble the tap if the product or...

Page 20: ...Warning Do not submerge lids equipped with lighting in any type of liquid Before starting the cleaning and sanitizing operations of the lid remove it from the machine as described in the previous cha...

Page 21: ...roduce the auger engaging head C with shaft D Check that the gasket J is placed in its lodging Note Rotate the auger to engage it Set the bowl back in place slightly raise head C of the auger so that...

Page 22: ...tied and cleaned every time the red float installed in the grid rises into view Holding the drainage hose firmly lift the tray with the grid on top of it and pull it out Wash the tray and grid separat...

Page 23: ...y clean the condenser situated inside the machine Warning Removing safety guards will expose some sharp surfaces of the machine Warning A dirty condenser will impair machine performance To access the...

Page 24: ...n original spare part It is forbidden to use the machine when even only one of its components is faulty or worn Users are forbidden to perform periodic maintenance 8 Disposal Electric and electronic e...

Page 25: ...es not make granitas The switch is positioned on O Section 6 Press the switch into position I The machine is near sources of heat Install the machine in a more suitable place There is insufficient ven...

Page 26: ...26 NARVON 10 BASIC WIRING DIAGRAMS MODEL 378SM1 115 Volt MODEL 378SM2 115 Volt 0 I I 0 0 I 0 I I 0 II t F N II II I I I 0 0 I 0 I I 0 F N...

Page 27: ...27 NARVON MODEL 378SM3 115 Volt N F 0 I I 0 I 0 0 I I I II II II I 0 I...

Page 28: ...MIXING MOTOR SWITCH I M3 TANK 3 MIXING MOTOR SWITCH L L LIGHTED COVER LAMP L L 1 TANK 1 LIGHTED COVER LAMP L L 2 TANK 2 LIGHTED COVER LAMP L L 3 TANK 3 LIGHTED COVER LAMP L MC COMPRESSOR INDICATOR LI...

Page 29: ...ncludes installation in any and all outdoor or mobile applications Failure to properly maintain the unit This includes but is not limited to basic preventative maintenance like cleaning It is the oper...

Page 30: ...of more of these things will extend processing time Food Truck and Outdoor Commercial use Warranty Valid only in the Contiguous United States Narvon Beverage Equipment warrants new equipment sold to...

Reviews: