S - Service clearance 24 inches (610mm) or more.
C - Combustible floor (but not carpet or non-ceramic tile).
All models approved for closet installation.
Plenum
1/2" (13mm)
on all sides
0"
0"
0"
0"
H3.6A
WARNING
!
!
WHEN THIS FURNACE IS INSTALLED IN A STORAGE GARAGE, IT MUST BE INSTALLED
SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18” (457 mm)
ABOVE THE FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH
MAY BE PRESENT IN THE GARAGE.
THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY
VEHICLES.
FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING
IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
TABLE A - FURNACE DIMENSIONS
INPUT
Width
Depth
Height
Supply Air
Return Air
K/Btu/hr
A
B
C
(F x G)
(D x E)
40
17 1/2"
(445mm)
29 1/2"
(749mm)
34”
(864mm)
16 1/4" x 19 5/8"
(413mm x 499mm)
14" x 23"
(356mm x 584mm)
60
80
H12.6.11
H12.11.6
UPFLOW HORIZONTAL
TOP
0
0
PLENUM TOP
1/2" (13mm)
1/2" (13mm)
FRONT
0*
0*
BACK
0
0
SIDES
0
0**
BOTTOM
0***
0
FLUE PIPE
0
0
ENCLOSURE
CLOSET
CLOSET
TABLE B - MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
*24" (610mm) REQUIRED FOR SERVICE
**SUPPLY AIR OUTLET / 1/2"
(13mm)
RETURN AIR INLET
*** CERTIFIED FOR CLOSET INSTALATION ON COMBUSTIBLE FLOORING.
FIGURE 1 - FURNACE DIMENSIONS AND CLEARANCE TO COMBUSTIBLES
Summary of Contents for WSX-EN Series
Page 27: ...W415 2845 B 11 10 20 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 2845 B 11 10 20 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 62: ...W415 2845 B 11 10 20 62 IOM IOM 44 1 24 0 NOTES...
Page 153: ...W415 2845 B 11 10 20 153 MU...
Page 154: ...W415 2845 B 11 10 20 154 MU...
Page 155: ...W415 2845 B 11 10 20 155 MU...