W415-2845 / B / 11.10.20
49
IOM
18.3
BLOWER AIRFLOW
H3.77
DISCONNECT THE ELECTRICAL SUPPLY TO THE FURNACE BEFORE ATTEMPTING TO
CHANGE THE BLOWER SPEED. FAILURE TO DO SO COULD RESULT IN ELECTRICAL
SHOCK RESULTING IN PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
18.4 CONTINUOUS FAN OPERATION
H22.3.3
When the thermostat continuous fan (G) switch is on without a call for heat or cooling, the indoor fan is
immediately energized on low heat speed. The fan remains energized as long as the call for fan remains
without a call for heat or cooling. This feature allows continuous circulation of air between calls for heating or
cooling.
If a call for heat (W) occurs during continuous fan, the blower will remain energized, the call for heat overides
the call for fan.
If a call for cool (Y) occurs simultaneously with the call for fan (G), the call for cool overrides the call for fan.
See Air Flow Data table.
TABLE 7A
FIGURE 33
ESP (in. WC)
Low Heat (1)
High Heat (2)
1.5T Cool (3)
2.0T Cool (4)
2.5T Cool (5)
0.5
167
477
364
696
912
0.1
515
637
549
809
1013
ESP (in. WC)
Low Heat (1)
High Heat (2)
2.0T Cool (3)
2.5T Cool (4)
3.0T Cool (5)
0.5
528
842
680
1010
1209
0.12
747
1002
860
1165
1327
ESP (in. WC)
Low Heat (1)
High Heat (2)
2.0T Cool (3)
2.5T Cool (4)
3.0T Cool (5)
0.5
583
1028
712
931
1328
0.2
755
1146
866
1068
1418
Model: WSX040T2AA
Model: WSX060T3AA
Model: WSX080T3AA
Contact your authorized dealer or refer to Blower Air
fl
ow Speci
fi
ca
Ɵ
on Sheet on the Napoleon website for
more informa
Ɵ
on.
-EN
-EN
-EN
Summary of Contents for WSX-EN Series
Page 27: ...W415 2845 B 11 10 20 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 2845 B 11 10 20 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 62: ...W415 2845 B 11 10 20 62 IOM IOM 44 1 24 0 NOTES...
Page 153: ...W415 2845 B 11 10 20 153 MU...
Page 154: ...W415 2845 B 11 10 20 154 MU...
Page 155: ...W415 2845 B 11 10 20 155 MU...