18
W415-0771 / B / 08.10.09
A = 2’ (61 cm)
Chimney should be at least 2 ft (61 cm) above the high-
est section of the portion of the building or other obstacles
within 10 ft (305 cm) horizontally.
Chimney should also extend a minimum of 3 ft (91 cm)
above the roof where it passes through.
!
WARNING
CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE, CHIMNEY AND OTHER
PARTS NEEDED TO INSTALL THIS FURNACE. FAILURE TO DO SO MAY RESULT IN A FIRE ESPE-
CIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE UNIT OR CHIMNEY AND AIR SPACES ARE
BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
5.18 ELECTRICAL INSTALLATION
!
WARNING
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE CURRENT CAS22.1 CANADIAN ELECTRICAL CODE OR WITH
THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (CURRENT IN USA).
Your furnace must be wired to 220 volts power supply. Power connection cable is the thick black cable by the
junction box and loose end is in the fan box.
Wiring is as shown below.
Napoleon NCPF-110
JUNCTION BOX
TERMINALS
THERMOCORN MODEL NCPF-110 REV. 2
JUNCTION BOX - COLOUR CODED CHART
16
AMP
- 2 POLE
MAIN CURRENT
BREAKER
6
AMP
CURRENT
BREAKER,
GEARBOX
6
AMP
CURRENT
BREAKER,
BLOWER
2
AMP
CURRENT
BREAKER,
COMBUSTION F
A
N
ROOM
THERMOST
A
T
AC in
L1 L2
or
L N
GROUNDING POLE
ROOM
THERMOST
A
T
W385-0490
REVISION DATE:
AUGUST 08
PRODUCTION DATE:
JULY 09