32
W415-1539 / A / 04.19.16
ENEN
* Within the appliance enclosure a 3" (152mm)
clearance between the top of the vent pipe
and combustible materials is required. All other
clearances within the enclosure, including
where the vent pipe exits the enclosure are
subject to 2" (51mm) to the sides and bottom
and 3" (76mm) to the top for horizontal and 1"
(25mm) for vertical.
** See “VENTING” section.
2"
51mm
3"
152mm *
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
3"
76mm
57"
1448mm
MINIMUM
PLUS RISE**
NON-COMBUSTIBLE
COMBUSTIBLE
TOP OF ENCLOSURE
(COMBUSTIBLE)
STEEL STUD
FRAME
26 9/16"
675mm
MINIMUM
TOP OF
APPLIANCE
OPENING
25 5/8"
651mm
MINIMUM
63 1/2"
1613mm
MINIMUM
ENCLOSURE
HEIGHT
2"
51mm
HEAT
SHIELD
TOP OF ENCLOSURE
(COMBUSTIBLE)
STEEL STUD
FRAME
MINIMUM
HEIGHT
OF
NON-COMBUSTIBLE
MATERIAL
MINIMUM
ENCLOSURE
HEIGHT
HEAT SHIELD
NON-COMBUSTIBLE