2
W415-1539 / A / 04.19.16
ENEN
TABLE OF CONTENTS
1.0
INSTALLATION OVERVIEW
3
2.0 INTRODUCTION
4
2.1 DIMENSIONS
5
2.2 GENERAL
INSTRUCTIONS
6
2.3 GENERAL
INFORMATION
7
2.4
RATING PLATE / LIGHTING INSTRUCTION LOCATION
8
3.0 VENTING
9
3.1
VENTING LENGTHS AND COMPONENTS FOR DIRECT VENT INSTALLATIONS
9
3.2
TYPICAL VENT INSTALLATIONS
10
3.3
SPECIAL VENT INSTALLATION
11
3.3.1 PERISCOPE
TERMINATION
11
3.4
MINIMUM AIR TERMINAL LOCATION CLEARANCES
12
3.5
VENT APPLICATION FLOW CHART
13
3.6 DEFINITIONS
13
3.7
ELBOW VENT LENGTH VALUES
13
3.8 HORIZONTAL
TERMINATION
14
3.9 VERTICAL
TERMINATION
16
4.0 INSTALLATION
18
4.1
WALL AND CEILING PROTECTION
18
4.1.1 HORIZONTAL
INSTALLATION
19
4.1.2 VERTICAL
INSTALLATION
19
4.2
USING FLEXIBLE VENT COMPONENTS
20
4.2.1 HORIZONTAL
AIR
TERMINAL
INSTALLATION
20
4.2.2 VERTICAL
AIR
TERMINAL
INSTALLATION
21
4.2.3
APPLIANCE VENT CONNECTION
22
4.3
MOBILE HOME INSTALLATION
22
4.4 GAS
INSTALLATION
23
5.0 FRAMING
24
5.1 TWO
SIDED
APPLIANCE
26
5.2 ONE
SIDE
APPLIANCE
28
5.3 NAILING
TAB
INSTALLATION
30
5.4
MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
31
5.5
VENTILATION OPENINGS AND ENCLOSURE CLEARANCES
33
5.6
INSTALLING NON-COMBUSTIBLE BOARD
34
5.7 RECESSED
INSTALLATION
36
5.8
MINIMUM COMBUSTIBLE MANTEL CLEARANCES
37
6.0 FINISHING
38
6.1
SAFETY SCREEN INSTALLATION / REMOVAL
38
6.2
DOOR INSTALLATION / REMOVAL
40
6.3
GLASS MEDIA INSTALLATION
41
6.4
OPTIONAL ROCK / DRIFTWOOD PLACEMENT
42
6.5 LOGO
PLACEMENT
42
7.0 ELECTRICAL
CONNECTION
43
7.1
HARD WIRING CONNECTION
43
7.2
RECEPTACLE WIRING DIAGRAM
44
7.3
REMOTE RECEIVER INSTALLATION
44
7.4 SCHEMATIC
45
8.0 OPERATION
46
8.1 GENERAL
TRANSMITTER
LAYOUT
46
8.2
INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME
47
8.4 FLAME
HEIGHT
47
8.5
LED ON/OFF LIGHT CONTROL
48
8.6
CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION
49
8.7
CHILD PROOF FUNCTION
49
8.8
LOW BATTERY / MANUAL BYPASS
49
8.9
IN THE EVENT OF A POWER FAILURE
49
8.10 TIMED
BLOWER
50
9.0 OPERATING
INSTRUCTIONS
50
9.1 BLUETOOTH
CONTROL
51
9.2 CONNECTING
THE
eFIRE
CONTROLLER
APP
53
9.3
HOW TO USE THE FIRE CONTROLLER APP
54
10.0
ADJUSTMENT
56
10.1
RESTRICTING VERTICAL VENTS
56
10.2 PILOT
BURNER
ADJUSTMENT
56
10.3 VENTURI
ADJUSTMENT
57
10.4 FLAME
CHARACTERISTICS
58
11.0
MAINTENANCE
58
11.1 ANNUAL
MAINTENANCE
59
11.2 CONTROL
ACCESS
59
11.3 VALVE
REMOVAL
60
11.4 BURNER
REMOVAL
61
11.5
CONTROL MODULE REMOVAL
61
11.6 LED
REPLACEMENT
62
11.7
GLASS / DOOR REPLACEMENT
63
11.8
CARE OF GLASS
63
11.9
CARE OF PLATED PARTS
63
NOTE: The camera icon indicates video tutorials are available as additional reference, visit
http://www.napoleonfi replaces.com/category/product-support/support-centre/