NANAWALL HSW75 OWNER’S MANUAL
16
j.
Remove any dirt from the floor sockets,
pivot boxes and bottom door closers
k. Ensure that any lock and profile cylinder
can be moved easily
l.
For single/double action sliding panels,
check position of the reversing gear
GLASS INSTALLATION AND GLAZING
This section applies only if you need to install glass for
any reason. Proper glass installation is critical, as, with the
NanaWall single track sliding system, glass is a structural
part of the panel.
Glass, with appropriate dimensions, thickness and
specifications will be needed. Depending on the model,
widths of all glass panels may not be equal.
Contact
NanaWall for the glass dimensions. Please note that glass
is required to be safety glass – either fully tempered or
laminated as specified for a particular order. Check with
all applicable codes and regulations.
Glass shall meet the current requirements of ASTM C
1306 “Standard Specifications for Flat Glass” for quality,
thickness and dimensional tolerances. Tempered float
glass shall meet the current requirements of ASTM C
1048 “Standard Specifications for Heat-Treated Flat
Glass - Kind HS, Kind FT Coated and Uncoated Glass.”
All tempered glass shall have a permanent logo, which
signifies Safety Commission 16 CFR-1201 and the safety
glass test requirements of ANSI Z 97.1 (current editions)
or other equivalent safety standards.
Follow all proper applicable glass installation and glazing
techniques as recommended in the Flat Glass Marketing
Association (FGMA) “Glazing Manual” and “Sealant
Manual”. Always use suction cups to shift glass within an
opening. The panels would need to be removed from the
opening to install the glass. Panels can be laid flat on
sawhorses.
Please get in touch with NanaWall before you replace
a glass pane in order to get the right material and
instructions to glaze the panel!