background image

NANAWALL HSW75 OWNER’S MANUAL

Installation Instructions 

The installation of the HSW75 System requires a working

 

knowledge and experience in the use of tools,

 

equipment 

and methods necessary for the installation of

 

aluminum

 

doors, storefronts

,

 and/or partitions. This practice 

assumes a familiarity with preparing a proper and

 

structurally sound opening, proper structural support for

 

stacking bays and proper anchorage and assumes an

 

understanding of the fundamentals of building

 

construction that affect the installation of large

 

horizontal 

single track sliding systems. A crew of at least

 

2 persons 

is needed. These systems can be heavy. Use

 s

afe lifting 

techniques to avoid injury and product 

d

amage.

Highly recommended is using a

n independent

 NanaWall

 

C

ertified 

I

nstaller, if available, or, at least, an installer

 

who has some experience in installing NanaWall

 

systems.

IMPORTANT: 

READ COMPLETE INSTRUCTIONS 

BEFORE BEGINNING INSTALLATION. INSTALL AS 
RECOMMENDED; OTHERWISE, THE UNIT MAY 
NOT FUNCTION PROPERLY AND ANY WARRANTY, 
WRITTEN OR IMPLIED, WILL BE VOID.

CAUTION:  
As regulations governing the use of glazed windows,

 

doors, storefronts and/or partitions vary widely, it is the

 

responsibility of the building owner, architect, contractor

 

or installer to insure that products selected conform to all

 

applicable codes and regulations, including federal,

 

state

and local. Nana Wall Systems, Inc. can assume no

 

obligation or responsibility whatsoever for failure of the

 

building owner, architect, contractor

,

 or installer to

 

comply with all applicable laws and ordinances and

 

safety and building codes.

Please pay special attention to the thickness of glass. 

The NanaWall glass thickness for the panels is based 
on the Glass Association of North America (GANA) 
recommended minimum glass thickness for fully 
tempered Interior butt glazed fixed glass panels.

The HSW75 system is shipped with all necessary 
components. However, not included are screws, bolts, 
shims, etc. to anchor the unit to the opening. The frame 
is shipped knocked down and needs to be assembled. 
Panels are pre-assembled with glass, ready to be attached 
to the installed frame. In most cases, all rollers, pivots, 
brushes and lockings are pre-attached to the panels.

DESCRIPTION OF SUPPLIED PARTS 

 

First look for an envelope in the shipment, which contains 
drawings of the elevation, the layout of the unit and an 
Installation Manual. This information together with the 
Custom Product Drawings provided by NanaWall at the 
time of order will be needed for a successful installation. 
As there is 

no “standard” configuration

 for HSW75 units, 

see 

Diagram 1

 which shows the elevation and layout of 

a 5 panel unit to illustrate the installation process. Some 
items may not be applicable for your unit. Inspect the 
custom product drawing, indicating size, configuration 
and labeling of the unit ordered. 

Check all parts carefully before assembly. Depending on 
the unit ordered, some of these parts may already be pre-
installed on the panels. 

Check that the sizes of the frame 

components and panels match with what was ordered.

 

The elevation drawing shows the sequence and number 
of panels, which depends on the model ordered. 

The drawing is always viewed from the outside, but 
the locking shown is what is on the inside.

 The panels 

are pre-assembled with two upper carriers for each 
sliding panel and with specified locking. 

The sequence 

of labeling of panels starts from the left looking from 
outside with the left most panel labeled Panel #1.

Summary of Contents for HSW75

Page 1: ...ingle Track Sliding Frameless System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through NanaWall...

Page 2: ...s of glass The NanaWall glass thickness for the panels is based on the Glass Association of North America GANA recommended minimum glass thickness for fully tempered Interior butt glazed fixed glass p...

Page 3: ...E OF A 5 PANEL UNIT Panel 1 sliding panel Panel 2 sliding panel Panel 3 sliding panel Panel 4 sliding panel Panel 5 double action end panel non sliding with pivot box or double action end panel non sl...

Page 4: ...lean and dry location and protect against defacement or damage especially to the edges of panels PREPARATION OF THE OPENING AND SUPPORT STRUCTURE ABOVE Make rough opening width at least 1 2 wider than...

Page 5: ...lable please verify the type of sockets for this order If planning to cut into a post tensioned concrete for bottom door closers pivot boxes and sockets a structural engineer and architect has to be c...

Page 6: ...ews provided See Sheet 4 of the Installation Manual Make sure that the correct angles between segments are maintained and that the transitions between the track segments are perfectly aligned and smoo...

Page 7: ...FORCED TO ENSURE THAT THE UPPER TRACK IS NOT BOWED Upper track segments must be joined such that they are even tight and aligned perfectly Otherwise the running carriages may wear out prematurely whic...

Page 8: ...E HAS TO BE SECURED TO THE SOCKET IN THE PIVOT BOX IN THE FLOOR BEFORE THE SINGLE DOUBLE ACTION SLIDING PANEL CAN FUNCTION PROPERLY OTHERWISE IT WILL NOT BE STABLE AND CAN FALL AND HURT SOMEBODY C GAP...

Page 9: ...hanism is not in the way Make sure the panels are straight and the correct 4 mm gap between panels is maintained Start with the panel furthest away from the parking bay and add blue masking tape under...

Page 10: ...6 52 mm Please check custom product drawing for swing direction inside outside See Sheet 14 and 15 of the Installation Manual Mark this point and if concrete use a diamond core drill bit with 1 1 4 di...

Page 11: ...ip to the edge of the wall Make sure that the full underside of the box rests on a flush and level surface and fix it temporarily into place Then install the receiver box for the top axle by hanging i...

Page 12: ...ed Check if all angles are correct Each leg of the stacking bay track should be equidistant at all points Step F5 Correct any problems before you finish the trimming Do not attach any trimming directl...

Page 13: ...n edge bolt with hand or foot d Automatic Locking when adjacent panels are pulled together and properly aligned the bolt automatically engages 4 Note that there is a carrier at each upper corner of a...

Page 14: ...e head track and engages to the top rail Turn about 8 10 revolutions in a clockwise direction until there is a slight resistance 3 Release the Quick Release Lock on the pivot side to disengage the loc...

Page 15: ...ce Its appearance may be marred by harsh chemicals abuse or neglect Frequency of cleaning depends on exposure and needs For aluminum surfaces generally warm soapy water should be sufficient Stubborn s...

Page 16: ...licable codes and regulations Glass shall meet the current requirements of ASTM C 1306 Standard Specifications for Flat Glass for quality thickness and dimensional tolerances Tempered float glass shal...

Page 17: ...soap and fresh water at least every month and more frequently if necessary After washing the surface should be rinsed thoroughly with clean water and allowed to dry For cleaning do not use abrasive h...

Page 18: ...antial cracking chipping or peeling due to the deterioration of the finish exclusive of mechanical damage 2 chalking in excess of a numerical rating of 8 as per ASTM D 659 or 3 fading or color changes...

Page 19: ...e of the affected product in full satisfaction of its obligations Wood Wood components must be properly finished on all sides promptly after receipt of unit before installation of unit and prior to ex...

Page 20: ...Product selection application storage handling modification or waterproofing Movement of surrounding substrates including deflection of the header of more than or any other stresses on product Instal...

Page 21: ...faces Acts of God falling objects fire accidents external forces or other conditions beyond NanaWall s control Gas fill or retention levels in insulated glass units Field testing of Product Performanc...

Page 22: ...___________________________________ Project Address if different from above _____________________________________________________________ INSTALLATION Installer Name _______________________________ Ad...

Reviews: