Chap.6
z
Troubleshooting Guide
(12) E5: SLITTER ERROR
Pro-
ce-
dure
Is it normal when checked in
HELP mode (H-08)?
Is the connector firmly plugged
in to the sensor?
Is it normal when checked in
HELP mode (H-12, 13, 14, 15,
16, 28)?
Is the slitter positioning motor
running?
Is the belt tension too high?
Is the lead screw attached to
the pulley firmly set?
Slitter sensor
Slitter positioning
motor
1
2
3
4
5
6
Cause/Defective part
Result
Countermeasure
Yes
Yes
No
Yes
No
Yes
No
Yes
Go to procedure 3.
Replace faulty slitter sensors.
Plug the connector in firmly.
Replace the main PWB unit.
Replace faulty slitter positioning
motors.
Adjust the belt tension.
Tighten the pulley screw.
Replace the main PWB unit.
Items to be checked
HELP mode H-08
\
see p.143
HELP mode H-12
\
see p.144
HELP mode H-13
\
see p.144
HELP mode H-14
\
see p.144
HELP mode H-15
\
see p.144
HELP mode H-16
\
see p.145
HELP mode H-28
\
see p.148
(13) E6: DATA ERROR
Pro-
ce-
dure
Are the number of cuts and
scores greater than 17 when
calculated from table 1?
Cuts and scores
1
Cause/Defective part
Result
Countermeasure
Yes
No
Turn off AUTO CUT or reduce the
number of cuts and scores.
Replace the main PWB unit.