9 Troubleshooting
VJ-1604
Maintenance Manual
Rev.-00
9-32
17
Boot Transfer
failed
55-AA
Timeout
AA did not
replied to Step
55 of boot code
transfer.
Check connection
between control board
and MAIN board.
•
Reconnect control
board and MAIN
board.
•
Replace the cable
connecting control
board and MAIN
board.
•
Replace control
board.
•
Replace MAIN
board.
Replacing
HEATER
CONT
Board" p.4-
42
18
Boot Transfer
failed
55-AA reply
error xx
xx replied to
Step 55 of boot
code transfer.
19
Boot Transfer
failed
End code xx
An error (xx)
replied to
transfer end of
boot code.
20
Boot Transfer
failed
Echo timeout
Transfer
sequence echo
of boot code
did not reply.
21
Boot Transfer
failed
Echo error xx
Invalid transfer
sequence echo
of boot code
did not reply.
22
Internal error
Parameter save
error
Failed in
writing
parameter.
Normally not occurred.
FROM may be
defective.
Replace MAIN board.
23
Transfer failed
Wrong year
xxxx
Invalid year
data (xxxx)
received.
SODIMM or MAIN
board may be defective.
•
Replace SODIMM.
•
Replace MAIN
board.
24
Transfer failed
Wrong month
xx
Invalid month
data (xx)
received.
25
Transfer failed
Wrong date
xx
Invalid day
data (xx)
received.
26
Transfer failed
Wrong hour
xx
Invalid hour
data (xx)
received.
27
Transfer failed
Wrong min
xx
Invalid minute
data (xx)
received.
Table 9-8 Error Messages During File Transmission (Continued)
No.
Message
Event/
symptom
Check item
Action
Reference
Summary of Contents for ValuejetVJ-1604
Page 2: ......
Page 14: ...VJ 1604 Maintenance Manual 12 ...
Page 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Page 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Page 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Page 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Page 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Page 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Page 421: ......
Page 422: ......