VJ-1604
Maintenance Manual
5 Self-Diagnosis Mode
5-15
Rev.-00
5.5.4
Sensor Menu
This menu displays the sensor status on the operation panel.
If the displayed sensor status does not match the actual machine status, replace or adjust the relevant sensor
referring to the table below.
NOTE
For the following sensors, the sensor sensitivity is displayed in decimal number.
• P_EDGE sensor
Table 5-3 Inspection Items in Sensor Menu
No.
Sensor name
Status in display
Reference
1
CR_HP sensor
ON / OFF
2
Waste fluid tank sensor
ON / OFF
-
3
Wiper sensor
ON / OFF
-
4
Maintenance cover sensor (L/R)
Open / Close
-
5
Lever sensor
Up / Down
6
P_EDGE sensor
0 to 255
7
P_REAR sensor
0 to 255
8
Headslide
Low / High
9
Head thermistor
** ºC
10
H transistor 1, 2
** ºC
-