9 Troubleshooting
VJ-1604
Maintenance Manual
Rev.-00
9-62
15
Poor accuracy of
segment length in head
travel direction (main
scan direction).
1. Is working
environment
appropriate?
Use machine under specified
environment.
Choosing a
Place for the
Printer" p.3-6
2. Is CR belt tension
adjusted to
specification?
Adjust CR belt tension.
Speed
Reduction Belt
Tension
Adjustment"
p.7-27
3. Is T fence
contaminated?
•
Clean T fence.
•
If T fence is still
contaminated or
damaged, replace T
fence.
4. Internal process of
MAIN board assembly
may be abnormal.
Initialize parameters and
reenter or modify them.
Then, check machine
operation again.
Parameter
Initialization
Menu" p.5-47
16
Poor linearity in head
scan direction
(straightness)
1. Is suction fan run as
normal when checked
through "Test 6: Fan"
of self-diagnosis
function?
•
Check connection of
following MAIN board
assembly connectors.
• Suction 1 - 4 cable:
J25 - J29
•
Replace suction fan
assembly.
•
Replace cable of suction
fan that does not operate
normally.
2. Is PF driving pulley
loose?
Replace PF motor assembly.
Replacing PF
Motor
Assembly"
p.4-61
3. Is PF speed reduction
belt tension adjusted to
specification?
Adjust PF speed reduction
belt tension.
Confirming
Completion of
Installation to
Plotter" p.7-14
Table 9-11 Symptoms, Check Items and Actions for Printing Problems (Continued)
No.
Symptom
Check item
Action
Reference
Summary of Contents for ValuejetVJ-1604
Page 2: ......
Page 14: ...VJ 1604 Maintenance Manual 12 ...
Page 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Page 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Page 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Page 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Page 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Page 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Page 421: ......
Page 422: ......