VJ-1604
Maintenance Manual
9 Troubleshooting
9-31
Rev.-00
16
Boot Transfer
failed
Opening seq.
failed
Opening
sequence of
boot code
transfer failed.
•
Check connection
between control
board and MAIN
board.
•
Check if the green
LED on control
board is lit.
•
Check if the red
LED on control
board is blinking.
•
Reconnect control
board and MAIN
board. Otherwise,
replace the cable
connecting control
board and MAIN
board.
•
If the green LED on
control board is off
after the power is
turned on, replace
the control board.
•
If the red LED is
blinking and there is
no problem at
connection between
control board and
MAIN board, try to
reinstall firmware.
•
If the red LED is
off, perform the
following
procedures.
1. Turn off the power,
then switch the DIP
switch as follows:
1: ON
2: ON
3: ON
4: OFF
2. Start the board
manager mode.
3. Reinstall firmware.
4. Turn off the power,
then switch the DIP
switch as follows:
1: ON
2: OFF
3: ON
4: OFF
5. Turn on the power,
then check if the red
LED is blinking.
Replacing
HEATER
CONT
Board" p.4-
42
Working with
Dedicated
Network
Software"
p.7-7
Table 9-8 Error Messages During File Transmission (Continued)
No.
Message
Event/
symptom
Check item
Action
Reference
Summary of Contents for ValuejetVJ-1604
Page 2: ......
Page 14: ...VJ 1604 Maintenance Manual 12 ...
Page 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Page 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Page 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Page 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Page 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Page 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Page 421: ......
Page 422: ......