A Murrelektronik Company
A Murrelektronik Company
33
C. COUNTER NOTES
1. Turning off the counter does not reset the accumulative value of the counter, a reset is required to reset the count.
2. If roll-over is not selected the counter will only accrue up to the setpoint entered.
3. Designated outputs can be controlled by the counter to work asynchronous to the controller, when setpoint has been reached,
the output will shut off if the enable bit is on. Please note the output must be turned on as it will not automatically turn on when
the counter is on.
4. Turning the counter OFF will not clear the current count value or set point.
5. A counter reset does not clear the counter set point.
6. A counter reset will clear the current count and does not turn the counter OFF.
7. The Roll-Over signal will not change the Output3A and Output4A Enable function.
D. COUNTER OPERATION EXAMPLES
Counter Basic
Set Point zero, Reset off, Roll Over off
1
2
11
10
9
8
7
6
5
4
3
0
0
7
7
6
5
4
3
2
1
0
0
0
7
7
7
6
5
4
3
2
1
7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
2
1
0
0
0
1
0
0
0
3
3
3
2
1
0
0
2
1
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
3
3
3
3
2
1
0
0
0
3
3
3
3
3
3
3
2
1
3
0
3
3
3
3
3
3
3
3
3
3
0
3
3
3
3
3
3
3
3
3
3
3
Counter Input
Counter On
Counter
Set Point
Counter Input
Counter On
Counter
Set Point
Reset
Counter Input
Counter On
Counter
Set Point
Counter - Using Reset
Set Point zero, Roll Over off
1
2
11
10
9
8
7
6
5
4
3
0
0
7
7
6
5
4
3
2
1
0
0
0
7
7
7
6
5
4
3
2
1
7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
2
1
0
0
0
1
0
0
0
3
3
3
2
1
0
0
2
1
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
3
3
3
3
2
1
0
0
0
3
3
3
3
3
3
3
2
1
3
0
3
3
3
3
3
3
3
3
3
3
0
3
3
3
3
3
3
3
3
3
3
3
Counter Input
Counter On
Counter
Set Point
Counter Input
Counter On
Counter
Set Point
Reset
Counter Input
Counter On
Counter
Set Point
Counter - Using Set Point
Set Point set, Reset off, Roll Over off
1
2
11
10
9
8
7
6
5
4
3
0
0
7
7
6
5
4
3
2
1
0
0
0
7
7
7
6
5
4
3
2
1
7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
2
1
0
0
0
1
0
0
0
3
3
3
2
1
0
0
2
1
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
11
10
9
8
7
6
5
4
3
0
0
3
3
3
3
3
3
2
1
0
0
0
3
3
3
3
3
3
3
2
1
3
0
3
3
3
3
3
3
3
3
3
3
0
3
3
3
3
3
3
3
3
3
3
3
Counter Input
Counter On
Counter
Set Point
Counter Input
Counter On
Counter
Set Point
Reset
Counter Input
Counter On
Counter
Set Point