5.2.5 PWM(i) OPERATION
The PWM(i) control has more status and control commands than the standard PWM control. The module takes a setpoint for the current control
and closes the loop according to the values put into the Kp and Ki. The module also sends the current reading back via a current status message.
All commands and status are shown below.
Loop Tuning (Kp and Ki)
J1939 Output Configuration 3*
Value
Name
Data Type
Byte
Bits
Description
84 (0x54)
Command
Byte
1
Command for index pointer (which message your sending)
INMODE8A
4 bit
2
1,2,3,4
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x7=Digital Positive Frequency,
0x8= High Speed Counter
INMODE8B
5,6,7,8
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x3= 4-20ma (4000-20000),
0x4= 0-5V DC (0-5000, 0x5= 0-10V DC (0-10000), 0x6= 0-32V DC (0-32000),
0x9= Ratiometric (0-100.0% of source V DC)
Port 1A Kp
Byte
3
Output 1A proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 1A Ki
4
Output 1A integral set point (0-250 = 0-2.50, >250=0) default 100
Port 1B Kp
5
Output 1B proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 1B Ki
6
Output 1B integral set point (0-250 = 0-2.50, >250=0) default 100
Port 2A Kp
7
Output 2A proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 2A Ki
8
Output 2A integral set point (0-250 = 0-2.50, >250=0) default 100
J1939 Output Configuration 4*
Value
Name
Data Type
Byte
Bits
Description
85 (0x55)
Command
Byte
1
Command for index pointer (which message your sending)
Port 2B Kp
2
Output 2B proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 2B Ki
3
Output 2B integral set point (0-250 = 0-2.50, >250=0) default 100
Port 3A Kp
4
Output 3A proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 3A Ki
5
Output 3A integral set point (0-250 = 0-2.50, >250=0) default 100
Port 3B Kp
6
Output 3B proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 3B Ki
7
Output 3B integral set point (0-250 = 0-2.50, >250=0) default 100
Not used
8
* Recommended starting values: Kp = 70, Ki = 30.
* Recommended starting values: Kp = 70, Ki = 30.
J1939 Output Configuration 4
Value
Name
Data Type
Byte
Bits
Description
85 (0x56)
Command
Byte
1
Command for index pointer (which message your sending)
Port 4A Kp
2
Output 4A proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 4A Ki
3
Output 4A integral set point (0-250 = 0-2.50, >250=0) default 100
Port 4B Kp
4
Output 4B proportional set point (0-250 = 0-2.50, >250=0) default 100
Port 4B Ki
5
Output 4B integral set point (0-250 = 0-2.50, >250=0) default 100
Not used
6
Not used
7
Not used
8